Honeywell R8184G4009 Non-Recycle Oil Burner Control with Safety Timing, 120/220/240 volt
- Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
- Solid state flame sensing circuit
- LED on terminal strip indicates system lockout
- Remote lockout indication
- Enclosed safety switch with external reset button
- Manual trip lever opens safety switch for system maintenance
- Mounts on standard 4 x 4" junction box
- C554A cadmium sulfide flame detector and 24 VAC thermostat required
- With 15 sec safety timing, alarm outputs and manual safety switch
Honeywell R75-40
Item#:
R75-40
Manufacturer Item:
R8184G4009
Manufacturer:
HONEYWELL
Honeywell Protectorelay R8184G4066/U Non-Recycle Oil Burner Control with Safety Timing, 4-1/8" W x 4-3/8" H x 2-1/2" Depth
- Provides automatic, non-recycling control of an intermittent ignition oil burner system
- Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
- Solid state flame sensing circuit
- LED on terminal strip indicates system lockout
- Remote lockout indication
- Enclosed safety switch with external reset button
- Manual trip lever opens safety switch for system maintenance
- Mounts on standard 4 x 4" junction box (select models may be mounted directly on burner housing)
- C554A cadmium sulfide flame detector and 24 volts thermostat required
- 15 second safety timing, alarm outputs, and manual safety switch
- Intermittent ignition timing
Honeywell R75-37
Honeywell Protectorelay R8184G4082 Oil Burner Control
- With 45 sec safety timing and alarm outputs
- Provides automatic, nonrecycling control of an intermittent ignition oil burner system
- Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
- Solid state flame sensing circuit
- Enclosed safety switch with external reset button
- Manual trip lever opens safety switch for system maintenance
- Mounts on standard 4 x 4" junction box, select models may be mounted directly on burner housing
- C554A cadmium sulfide flame detector and 24 VAC thermostat required
- 75 VA at 120/240 VAC, 50-60 Hz, 25 VA at 24V, 50-60 Hz alarm load ratings(pilot duty)
Honeywell R75-44
Carlin Parts 6020002S015120 CAD Cell Oil Primary Control, 15 sec Trial
- Interrupted duty ignition
- Recycle on flame failure
- Serviceman reset protection (latch-up after 3-consecutive lockouts)
- Diagnostic LED
- Valve delay on/motor delay off (pre/post-purge)
- 15 sec trial for ignition (TFI) other timings available
- 1.3 sec flame failure response time (FFRT)
- Alarm contacts
- Thermostat/aquastat compatible
- SMC (safety monitoring circuit) technology
Carlin Parts R77-44
Item#:
R77-44
Manufacturer Item:
6020002S015120
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Sid Harvey R82-2 Cadium Sulfide Flame Detector Kit, 60"Lead f/ A, E, J, & P Type
- For sequencing oil burner systems use with protectorelay oil primary controls such as R4166, R4184, R8182, R8184, and R8404.
- 2-piece model cell plug ins.
- Includes: 4 different style mounting brackets oil line bracket, cad cell eye, 60" leads
Honeywell R82-2
Item#:
R82-2
Manufacturer Item:
C554A1463
Manufacturer:
MITCO MFG.
Carlin Parts 42230-02S CAD Cell Oil Primary Control for Thermostat/Aquastat Compatible, 120 VAC, 500 watt
- Interrupted duty ignition for high efficiency
- SMC technology for safety monitoring
- Diagnostic LED indicators
- Secondary burner control has a input voltage rating of 120 VAC, input frequency rating of 60 Hz and input power rating of 10 VA from limit circuit
- 15 sec trial for Ignition 40200 (1.3 sec flame failure response time (FFRT))
- 30 sec trial for Ignition 42230 (1.3 sec flame failure response time (FFRT)
- Recycle on flame failure
- It has a temperature rating of 32 - 140 deg F and resistive rating of 1500 ohm
- Valve delay on/motor delay off for economic as well as efficient performance
- It has a motor load of 10 FLA/60 LRA and ignitor load of 120 VAC at 60 Hz
- 500 VA motor load
Carlin Parts R75-45
Item#:
R75-45
Manufacturer Item:
4223002S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Honeywell 120320 Cad Cell Eye for Use with Oil Primary Control in Burner
Honeywell R82-1
Item#:
R82-1
Manufacturer Item:
120320/U
Manufacturer:
HONEYWELL
Carlin Parts 48245S Intermittent Duty Oil Burner Primary Control, 120 VAC
- 45 sec trial for ignition
- Red LED lockout indicator
- Thermostat/aquastat compatible SMC (safety monitoring circuit) technology
- 5 amp full load, 60 amp locked rotor motor load
- 120 VAC, 60 Hz, 500 VA igniter load
Carlin Parts R75-47
Item#:
R75-47
Manufacturer Item:
48245S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Oilco OC-10 CAD Cell Eye for Oil Primary Controls
Sid Harvey R80-100
Item#:
R80-100
Manufacturer Item:
OC-10
Manufacturer:
OILCO COMPANY
Riello 20132573 Cad Cell Eye for Use with Oil Primary Control
Riello Parts 20132573
Item#:
20132573
Manufacturer Item:
20132573
Manufacturer:
RIELLO CORP OF AMERICA
Riello 20010004 Primary Control for R40 F3-F5-F10-F15-F20, BF3, BF5 Oil Burners with Manual and 530SE/C24V Hydraulic Air Shutter
Riello Parts 20010004
Item#:
20010004
Manufacturer Item:
20010004
Manufacturer:
RIELLO CORP OF AMERICA