Brand Name
Type
Pipe Size
Connection Type
Voltage
|◀ 1 - 12 of 121 ▶|
View:
These 2-position (open/close) control actuators are used with VCZ 1000, 1100, 6000 and 6100 series hydronic valves in a normal indoor environment to provide quick opening/closing to control the flow of hot and/or chilled water or glycol solution to 60% concentration. They are designed for on-off "zone" control of heating/cooling systems, or to control individual fan coil, baseboard radiator or convector applications. Depending on the model selected, the actuator can be controlled by a low or line VAC age SPST or SPDT controller, such as a room thermostat, aquastat or flow switch.
  • Double insulated actuator
  • Quick and easy replacement of moving parts
  • Actuator head installation does not require draining the system
  • Selectable/switchable electronic fail safe normally open or normally closed
  • Self alignment shaft adapter
  • SPST control signal
Sid Harvey Item #:VC8114ZZ11: Replaces Part #:'s : L40-119,
,


VC8114ZZ11

Item#:
VC8114ZZ11
Manufacturer Item:
VC8114ZZ11
Manufacturer:
HONEYWELL
White Rodgers Cooling Controls F19-0104 2-Wire Motor Assembly for 2-Wire Zone Valves 1361-102, -103, -104
Sid Harvey Item #:B163-113: Replaces Part #:'s : 3C719,

White Rodgers B163-113

Item#:
B163-113
Manufacturer Item:
F19-0104
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Honeywell V5013N1089 3-Way Mixing Valve 1-1/2",
,


V5013N1089

Item#:
V5013N1089
Manufacturer Item:
V5013N1089
Manufacturer:
HONEYWELL
White Rodgers Cooling Controls F19-0097 3-Wire Motor Assembly for 3-Wire Zone Valves 1311-102, -103, -104
Sid Harvey Item #:B163-112: Replaces Part #:'s : 3C7193,

B163-112

Item#:
B163-112
Manufacturer Item:
F19-0097
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Taco A3023522 Polyamide 4-Wire Thermal Actuator, 24 VAC Plus 20% Minus 4-wire thermal actuators mount directly onto TruFLOW Classic, TruFLOW Jr. valved, stainless-steel and EP heating manifolds. The actuators provide individual loop flow control on multi-zoned manifolds and feature an end switch for activation of a relay (pump), heat plant or other auxiliary devices. All adapter rings to mount to Uponor manifolds are included in the package.,


A3023522

Item#:
A3023522
Manufacturer Item:
A3023522
Manufacturer:
Uponer
Taco ZA024Q4A2 Actuator Head Zone Sentry Valves 24 VAC,
,


ZA024Q4A2

Item#:
ZA024Q4A2
Manufacturer Item:
ZA024Q4A2
Manufacturer:
TACO INC.
Caleffi Z-one Z1 Normally Closed Actuator With 18" Wire Microswitch
  • Z1 series normally closed actuator fits on Z2 and Z3 series valve bodies with the push of a butTon
  • 7/8" knockout for 1/2" conduit connector
  • With 18" wire microswitch
,
,


Z111000

Item#:
Z111000
Manufacturer Item:
Z111000
Manufacturer:
CALEFFI NORTH AMERICA, INC.
Honeywell 40003918-006/U Adapter Kit for V4043 or V8043 2-Way Zone Valves
Sid Harvey Item #:B163-3: Replaces Part #:'s : 40629,
,


B163-3

Item#:
B163-3
Manufacturer Item:
40003918-006
Manufacturer:
HONEYWELL
Bell & Gossett 189139 Bonnet and Retainer Assembly for Comfort-Trol CT-24, CTS-7524, CTF-10024 Zone Valve
  • Includes stem
Sid Harvey Item #:189139: Replaces Part #:'s : 3582,
,


189139

Item#:
189139
Manufacturer Item:
189139
Manufacturer:
BELL & GOSSETT ITT
Honeywell V8043E1004/U Brass 2-Way 2-Position Normally Closed Low VAC age Straight-Thru Zone Valve, 1/2", Sweat
  • On-off low VAC age valves consist of an actuator and valve assembly for controlling the flow of hot water
  • Manual opener for valve operation on power failure, valve returns to automatic position when power is restored
  • All models may be installed without disassembling the valve
  • Compact construction for easy installation
  • Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
  • Actuator motor may be replaced without removing the valve body or draining the system
  • Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water
  • 15 sec open time
  • 18" lead electric connection
  • Spring return to close valve action
  • 50 VA pilot duty at 24 VAC , 4.4 amp running with 26.4 amp inrush at 120 VAC end switch rating
  • NO SPST auxillary end switch
  • Buna-N (NBR) rubber ball plug/ball/disc material
  • EPDM rubber packing material
  • Mounted in any position on a vertical line
,
,


B163

Item#:
B163
Manufacturer Item:
V8043E1004
Manufacturer:
HONEYWELL
Honeywell V8043F1028/U Brass 2-Way 2-Position Normally Closed Low VAC age Straight-Through Motorized Zone Valve, 1/2", Sweat
  • 2-way on-off low VAC age valves consist of an actuator and valve assembly for controlling the flow of hot water
  • Manual opener for valve operation on power failure, valve returns to automatic position when power is restored
  • All model may be installed without disassembling the valve
  • Compact construction for easy installation
  • Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
  • Actuator motor may be replaced without removing the valve body or draining the system
  • The valve can be mounted in any position on a vertical line
  • Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water
  • 15 sec nominal open timing
  • Screw terminal block electric connection
  • Spring return to close valve action
  • No SPST auxiliary end switch
  • 50 VA pilot duty at 24 VAC , 4.4 amp running with 26.4 amp inrush at 120 VAC end switch rating
  • Buna-N (NBR) rubber plug
  • Brass case, sector gears, stainless steel cover actuator
Sid Harvey Item #:B163-4: Replaces Part #:'s : 12793,
,


B163-4

Item#:
B163-4
Manufacturer Item:
V8043F1028
Manufacturer:
HONEYWELL
Honeywell Home V8043E1061/U Brass 2-Way 2-Position Normally Closed Low VAC age Straight-Thru Zone Valve, 3/4 Inch, Sweat
  • On-off low VAC age valves consist of an actuator and valve assembly for controlling the flow of hot water
  • Manual opener for valve operation on power failure, valve returns to automatic position when power is restored
  • All models may be installed without disassembling the valve
  • Compact construction for easy installation
  • Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
  • Actuator motor may be replaced without removing the valve body or draining the system
  • Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water
  • 15 sec open time
  • 18" lead electric connection
  • Spring return to close valve action
  • 50 VA pilot duty at 24 VAC , 4.4 amp running with 26.4 amp inrush at 120 VAC end switch rating
  • NO SPST auxillary end switch
  • Buna-N (NBR) rubber ball plug/ball/disc material
  • EPDM rubber packing material
  • Mounted in any position on a vertical line
Sid Harvey Item #:V8043E1061: Replaces Part #:'s : 1C634,
,


V8043E1061

Item#:
V8043E1061
Manufacturer Item:
V8043E1061
Manufacturer:
HONEYWELL
|◀ 1 - 12 of 121 ▶|