Aquastat controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. Honeywell's L4006 are used in applications that utilize the existing wells.
  • Totally enclosed micro switch snap acting switches operate on temperature rise to setpoint
  • Visible control point scale and external adjustments screw permit easy setting
  • Horizontal or vertical insertion of the sensing element
  • Direct/well immersion of the sensing element
  • Remote bulb model may be used to sense air temperature in ducts and in outside air sensing applications
  • Contacts break on temperature rise
  • Screw terminals wiring
Sid Harvey Item #:C290-6A: Replaces Part #:'s : L39-938,
,



Honeywell C290-6A

Item#:
C290-6A
Manufacturer Item:
L4006E1091
Manufacturer:
HONEYWELL
Honeywell L8124G1020 High Limit Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
  • Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Electrical burner rating: full load - 7.4 amp at 120 VAC line voltage, 3.7 amp at 240 VAC; locked rotor - 44.4 amp at 120 VAC line voltage, 22.7 amp at 240 VAC
  • Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor Honeywell L8124G1020 High Limit Triple Aquastat Relay, 120 VAC at 60 Hz, SPSTSid Harvey Item #:C317-8: Replaces Part #:'s : C318-8R,
    ,



    Honeywell C317-8

Item#:
C317-8
Manufacturer Item:
L8124G1020
Manufacturer:
HONEYWELL
Honeywell L8124A1015 Triple Aquastat Relay, 120 VAC
  • Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Electrical burner rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
  • Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
  • Includes 3" insertion well and ground screw
Sid Harvey Item #:C317-2B: Replaces Part #:'s : AQU8124A1007-C317-2B | C317-2R | C317R,
,



Honeywell C317-2B

Item#:
C317-2B
Manufacturer Item:
L8124A1015
Manufacturer:
HONEYWELL
Honeywell L8148J1009/U Aquastat Relay, 120 VAC at 60 Hz, SPST, 120 - 240 deg F High Limit, 8 deg F Fixed Differential
  • Immersion-type controllers that combine high limit protection with switching relay control of burner and circulator motors
  • High limit opens burner circuit only
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • 1-1/2 - 3" depth less well insulation
  • Electrical burner rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC; millivolt: 0.25 amp at 1/4 - 12 VDC
  • Electrical circulator rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC Honeywell L8148J1009/U Aquastat Relay, 120 VAC at 60 Hz, SPST, 120 - 240 deg F High Limit, 8 deg F Fixed DifferentialSid Harvey Item #:C312-9: Replaces Part #:'s : L8148E1000,
    ,




    Honeywell C312-9

Item#:
C312-9
Manufacturer Item:
L8148J1009
Manufacturer:
HONEYWELL
Honeywell ST9103A1002 Electronic Fan Timer For Control of Burner and Circulating Fan Operations in an Oil Furnace, 18 - 30 VAC
  • Central appliance wiring point simplifies service
  • Oil burner primary control
  • Fixed or field adjustable heat fan on delay
  • Field adjustable heat fan off delay
  • Controls 2-speed circulating fan
  • Fixed 45 sec heat fan on delay
  • Heat fan off delay - adjustable 60, 90, 120, 150 sec (set at 150 sec)
  • Fixed 0 sec cool fan on delay
  • Fixed 0 sec cool fan off delay
Sid Harvey Item #:C419-1: Replaces Part #:'s : L40-047,

,



Honeywell C419-1

Item#:
C419-1
Manufacturer Item:
ST9103A1002
Manufacturer:
HONEYWELL
Honeywell Winter Watchman S483B1002/U Beige Non-Programmable Thermostat, 120 VAC , 30 - 60 deg F
  • Completes circuit to household lamp on temperature fall, indicating inoperative heating equipment
  • Plugs directly into wall outlet
  • Lamp plugs into receptacle at bottom of winter watchman device
  • Useful when house is unoccupied to notify a neighbour of a temperature drop so heating source fault can be rectified before freeze-up occurs
  • Not precision calibrated for use as a thermostat
Sid Harvey Item #:C138-1: Replaces Part #:'s : 12515,
,



HONEYWELL C138-1

Item#:
C138-1
Manufacturer Item:
S483B1002
Manufacturer:
HONEYWELL
Honeywell C7250A1001 Sensor MA 20K,
,



honeywell c7250a1001

Item#:
C7250A1001
Manufacturer Item:
C7250A1001
Manufacturer:
HONEYWELL
Honeywell L8124C1003 Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
  • Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water service
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Electrical burner rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC line voltage; at locked rotor: 44.4 amp at 120 VAC, 22.7 amp at 240 VAC line voltage
  • Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
  • 1-1/2" depth insulation
Sid Harvey Item #:C317-5: Replaces Part #:'s : 30702,
,




Honeywell C317-5

Item#:
C317-5
Manufacturer Item:
L8124C1003
Manufacturer:
HONEYWELL
Resideo C554A1463 Cadmium-Sulfide Flame Detector,
,



honeywell c554a1463

Item#:
C554A1463
Manufacturer Item:
C554A1463
Manufacturer:
HONEYWELL
Aquastat controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. Honeywell's L4006 are used in applications that utilize the existing wells.
  • Totally enclosed micro switch snap acting switches operate on temperature rise to setpoint
  • Visible control point scale and external adjustments screw permit easy setting
  • Horizontal insertion of the sensing element
  • Direct/well immersion of the sensing element
  • Remote bulb model may be used to sense air temperature in ducts and in outside air sensing applications
  • Contacts make on temperature rise
  • Screw terminals wiring
Sid Harvey Item #:C290-1A: Replaces Part #:'s : L39-933,
,



Honeywell C290-1A

Item#:
C290-1A
Manufacturer Item:
L4006B1163
Manufacturer:
HONEYWELL
Honeywell L8124L1011 High Limit Triple Aquastat Relay, 24/120 VAC at 60 Hz, SPST
  • Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Electrical burner rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.7 amp at 240 VAC locked rotor
  • Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
Sid Harvey Item #:C317-11: Replaces Part #:'s : AQU8124L1011-C317-11 | C317-11R |,
,



Honeywell C317-11

Item#:
C317-11
Manufacturer Item:
L8124L1011
Manufacturer:
HONEYWELL
Honeywell T498B1512/U Brush Gold Non-Programmable Electric Heat Thermostat, 1H, 120/208/240/277 VAC , 40 - 80 deg F
  • Electric heat thermostats provide line VAC age control of electric heating systems
  • Easy to install, color coded leads
  • Rugged, plastic mounting base
  • Mount on standard 2 x 4" outlet box or 4 x 4" junction box
  • Select models include extra knob decal for recalibration, if necessary
Sid Harvey Item #:C182-5: Replaces Part #:'s : 12582,
,



HONEYWELL C182-5

Item#:
C182-5
Manufacturer Item:
T498B1512
Manufacturer:
HONEYWELL
|◀ 229 - 240 of 617 ▶|