S2K Commerce - Products Dropdown
ActionsS2K Commerce - Shopping Cart
ActionsS2K Commerce - Order Entry
ActionsBrand Name
Part Type
Capacity
White Rodgers Cooling Controls 50M56-743 Hot Surface Igniter Nitride Integrated Furnace Control, 25 VAC, 0.45 amp, 50/60 Hz
- System diagnostic LED with fault recall
- Multi speed circulator
- 1 or 2-stage gas valve
- Relay load ratings - 1.5 amp at 25 VAC 50/60 Hz 0.6 pico-F valve relay, 6 amp at 120 VAC 50/60 Hz (resistive) igniter relay, 2.2 amp full load, 3.5 amp locked rotor at 120 VAC inducer relay, 14.5 amp full load, 25 amp locked rotor at 120 VAC circulator relay
- Flame current requirements - 1 micro-amp DC minimum current to insure flame detection, 0.10 micro-amp DC maximum current for non-detection, 100 mega-ohm maximum allowable leakage resistance
- 0.8 sec flame establishing time, 2 sec flame failure response time
white rodgers 50m56-743
Item#:
50M56-743
Manufacturer Item:
50M56-743
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50A65-843 Universal Nitride Ignition Furnace Control, 25 The 50A55-843 universal silicon carbide integrated ignition module employs a microprocessor which continually monitors, analyzes and controls the proper operation of the gas burner, inducer and fan. This one module will replace most of the 50A5x-xxx integrated ignition carbide modules that have been manufactured by White-Rodgers for most OEM applications. The universal module includes an extensive cross-reference, additional jumper wires, additional wiring harness and a jumper for Trane applications. The module also has terminals for powering a humidifier and electronic air cleaner.Sid Harvey Item #:50A65-843: Replaces Part #:'s : D341213P01 | D341396P01 |,
Item#:
50A65-843
Manufacturer Item:
50A65-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
The 50A66-743 is an automatic gas interrupted ignition control that employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan. signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shutoff during normal operation. these controls incorporate system fault analysis for quick gas flow shutoff , coupled with automatic ignition retry upon sensing a fault correction.
- 3-fan speeds
- Remote flame sensing
- Humidifier and electronic air cleaner connections (optional)
- 1.5 amp valve relay
- 6 amp igniter relay
- 2.2 amp full load - 3.5 amp locked rotor inducer relay
- 14.5 amp full load - 25 amp locked rotor circulator relay
- Diagnostic indicator flash codes, controls gas valve, igniter, blower, inducer, humidifier and air cleaner
white rodgers 50a66-743
Item#:
50A66-743
Manufacturer Item:
50A66-743
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 5059-134 Pilot Relite Control, 24 VAC, 0.03 amp
- Generates spark pulse until flame is sensed through spark electrode
- Begins sparking immediately if flame extinguishes
- Rugged solid state module design
- Spike terminal high voltage and 1/4" spade terminals connection
white rodgers 5059-134
Item#:
5059-134
Manufacturer Item:
5059-134
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50A56-956 Replacement Integrated Furnace Control, 25 VAC , The 50A56-956 is an automatic gas interrupted ignition control that employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan. signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shutoff during normal operation. these controls incorporate system fault analysis for quick gas flow shutoff , coupled with automatic ignition retry upon sensing a fault correction.Sid Harvey Item #:50A56-956: Replaces Part #:'s : ICM2808,
white rodgers 50a56-956
Item#:
50A56-956
Manufacturer Item:
50A56-956
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50E70-820 HSI Integrated Furnace Control, 18 - 30 VAC, 60 Hz
- 1-stage applications
- 120 volt HSI ignition
- Adapter board and harness included
- For packaged units
- Flame current test pins
- Red and green status LEDs
- Standoffs/adapter board mounting
- 0.8 sec flame establishing time, 2 sec flame failure response time at 60 Hz
- Flame current requirements - minimum current to insure flame detection: 1 micro-amp DC, maximum current for non-detection: 0.1 micro-amp DC, maximum allowable leakage resistance: 100 mega-ohm,
Item#:
50E70-820
Manufacturer Item:
50E70-820
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50M56U-751 1-Stage HSI Integrated Furnace Control Kit forSid Harvey Item #:50M56U-751: Replaces Part #:'s : HK42FZ-004 | HK42FZ-007 | HK42FZ-008 | HK42FZ-009 | HK42FZ-011 | HK42FZ-013 | HK42FZ-016 | HK42FZ-034 | HK42FZ004 | HK42FZ007 | HK42FZ008 | HK42FZ009 | HK42FZ011 | HK42FZ013 | HK42FZ016 | HK42FZ034 |,
Item#:
50M56U-751
Manufacturer Item:
50M56U-751
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50C51-707 2-Stage HSI Integrated Furnace Control 24 VAC,
Item#:
50C51-707
Manufacturer Item:
50C51-707
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Beckett Parts Parts 7610B0001U AquaSmart Boiler Temperature Control (120V), Gas W/ Temp. ONLY Sensor (24V Burner Circuit)
Item#:
7610B0001U
Manufacturer Item:
7610B0001U
Manufacturer:
RW BECKETT CORP
Beckett Parts 7610A000LU Oil Aquasmart W/O Sensor 120 VAC,
,
,
Heat Controller Heating Parts 17B0001N04C Control Board
Item#:
17B0001N04C
Manufacturer Item:
17B0001N04C
Manufacturer:
ICP FAST PARTS
White Rodgers Cooling Controls 50T35-743 Circuit Board
White Rodgers 50T35-743
Item#:
50T35-743
Manufacturer Item:
B1809913S
Manufacturer:
WHITE-RODGERS DIV OF COPELAND