Brand Name
Part Type
Capacity
|◀ 49 - 60 of 81 ▶|
View:
ICM Controls ICM291 Ignition Module Pre-Purge: 45 seconds Trial for Ignition: 5+2 seconds,
,

Item#:
ICM291
Manufacturer Item:
ICM291
Manufacturer:
ICM INTERNATIONAL
White Rodgers Cooling Controls 21D83M-843 1-Stage Integrated Furnace Control Circuit Board Kit, 25 VAC, 0.45 amp, 60 Hz
  • Includes diagnostic indicator flash codes
  • 3-fan speeds
  • Remote flame sensing
Sid Harvey Item #:21D83M-843: Replaces Part #:'s : 50A62-120 | 50A62-121 | 50A62-820 | 50A65-120 | 50A65-121,
Item#:
21D83M-843
Manufacturer Item:
21D83M-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50M56X-843 Integrated Furnace Control Universal 1-Stage
Item#:
50M56X-843
Manufacturer Item:
50M56X-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Resideo Y8610U Intermittent 1 or 2-Rod Natural Gas/LP Pilot Retrofit Kit for Gas-Fired Atmospheric Furnaces, 24 VAC
  • Intermittent pilot retrofit kits save energy by converting atmospheric standing pilot systems to intermittent pilot
  • Use with natural or LP gas
  • Provides 100% pilot gas shutoff if pilot fails to light, after 6 min delay, trial for ignition is repeated
  • Ignition trail/delay sequence is repeated until the appliance lights or call for heat is removed
  • 2 sec flame failure response time
  • 0 or 30 sec pre-purge time
  • Ignition sequence - continuous retry, after trial for ignition, pilot gas shuts off for 5 min then another trial for pilot ignition takes place
  • Typical gas control - VR8204, VR8304
  • Ignition source - internal high voltage spark generator
  • Ignition trials to lockout - continuous retry
  • 1 amp pilot, 2 amp at 24 VAC maximum valve load
  • Q345, Q3451 typical ignition hardware
  • 15 or 90 sec lockout timing and ignition trial time
  • VR8204, VR8304 typical gas control
Sid Harvey Item #:Y8610U4001: Replaces Part #:'s : MHY8610U4001,
,

Item#:
Y8610U4001
Manufacturer Item:
Y8610U4001
Manufacturer:
HONEYWELL
International Comfort Products Fast Parts
Ion System 4 Zoning Panel

Item#:
SYST0101ZP
Manufacturer Item:
SYST0101ZP
Manufacturer:
INTERNATIONAL COMFORT PRODUCTS
White Rodgers Cooling Controls 50D50-801 Pilot Spark Ignition Control for Gas Appliance 18-30 VAC 0.2 amp,

Item#:
50D50-801
Manufacturer Item:
30W33
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50M56U-801Integrated HIS Furnace Control Board
  • System diagnostic LED with fault recall
  • Fused to protect low voltage system transformers
  • 3 fan speeds
  • Adapter harness for application flexibility
  • 15 sec pre-purge time
  • 30/45 heat delay for to fan on, 60/90/120/180 heat delay for to fan off, 2 cool delay for to fan on, 2/60 cool delay for to fan off, default setting
  • 5 sec post-purge
  • 0.8 sec max flame failure response time
  • 2 sec flame failure response time
  • 1.5 amp at 25 VAC 50/60 Hz for valve relay, 1.2 amp at 120 VAC 50/60 Hz for ignitor relay
  • Surface mount standoffs
  • 5 - 93% RH, non-condensing humidity
Sid Harvey Item #:50M56U-801: Replaces Part #:'s : ICM282 | ICM282A |,
Item#:
50M56U-801
Manufacturer Item:
50M56U-801
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Sealed Unit Parts Camstat L593BA Limit Control Switch, SPDT, 120 - 250 deg F Adjustable, 30 deg F Differential, 120/240 VAC
  • User adjustable temperature setting
Sid Harvey Item #:C375-75: Replaces Part #:'s : L36-138,
,

Item#:
C375-75
Manufacturer Item:
L593BA
Manufacturer:
SEALED UNIT PARTS CO, INC
Robertshaw Controls 35-605959-223 Natural/LP Gas Hot Surface Direct Spark Ignition Replacement 44L59, G765BCA-12,
,

Item#:
35-605959-223
Manufacturer Item:
35-605959-223
Manufacturer:
ROBERTSHAW CONTROLS CO.
The 50A66-743 is an automatic gas interrupted ignition control that employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan. signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shutoff during normal operation. these controls incorporate system fault analysis for quick gas flow shutoff , coupled with automatic ignition retry upon sensing a fault correction.
  • 3-fan speeds
  • Remote flame sensing
  • Humidifier and electronic air cleaner connections (optional)
  • 1.5 amp valve relay
  • 6 amp igniter relay
  • 2.2 amp full load - 3.5 amp locked rotor inducer relay
  • 14.5 amp full load - 25 amp locked rotor circulator relay
  • Diagnostic indicator flash codes, controls gas valve, igniter, blower, inducer, humidifier and air cleaner
Sid Harvey Item #:50A66-743: Replaces Part #:'s : 100925-01 | 100925-02 | 100925-03 | 10092501 | 10092502 | 10092503 |,
Item#:
50A66-743
Manufacturer Item:
50A66-743
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 5059-134 Pilot Relite Control, 24 VAC, 0.03 amp
  • Generates spark pulse until flame is sensed through spark electrode
  • Begins sparking immediately if flame extinguishes
  • Rugged solid state module design
  • Spike terminal high voltage and 1/4" spade terminals connection
Sid Harvey Item #:5059-134: Replaces Part #:'s : CNT01011,
Item#:
5059-134
Manufacturer Item:
5059-134
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Honeywell TP970A2004 Pneumatic Thermostat 60-90 2 Pipe,
,

Item#:
TP970A2004
Manufacturer Item:
TP970A2004
Manufacturer:
HONEYWELL
|◀ 49 - 60 of 81 ▶|