White Rodgers Cooling Controls C445-9 Close/Open On Rise Action Fan & Limit Control 120/240 VAC 5",
Item#:
C445-9
Manufacturer Item:
5D51-35
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 5D51-90 Close/Open on Rise Action Fan and Limit Control, 120/240 VAC
- Single element type for applications with narrow space limitations, regulates fan or blower operation and acts as high limit safety control
- Slotted mounting holes for easy installation
- Long terminal screws for wiring junctions can be made on terminal block
- Dial has individual pointers for fan cut-in and cut-out settings
- Removable solid copper jumper between fan and limit switches
- Summer fan switch for ventilation without changing control settings, has same fan and limit switch mechanism
Item#:
C445-10
Manufacturer Item:
5D51-90
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Heat Controller Heating Parts 17B0001N04C Control Board
Item#:
17B0001N04C
Manufacturer Item:
17B0001N04C
Manufacturer:
ICP FAST PARTS
Arzel PAN-HPP03 Control Panel 3-Zone 24 VAC Heat Pump
- Residential & light commercial four zones or less
- Single or multi-stage equipment
- Variable speed Furnace Air conditioner Heat pump Dual fuel
- Independent blower & compressor staging
- Outdoor Air Temperature (OAT) sensor
- Leaving Air Temperature (LAT) sensor
- LCD display
- Zone weight percentage
- Replaceable fuse protection
- Easy to use lever style terminals
- Manual pump switch opens all dampers for testing,
,
Arzel PAN-HPP04 Control Panel 4-Zone 24 VAC Heat Pump
Honeywell S87D1004 Direct Spark Ignition Control Module, 24 VAC, 60 Hz, 1-15/16" L x 4-1/16" W x 5-1/4" H
,
- Control ignition sequence and gas control operation
- Generate high voltage potential for main burner ignition
- Lockout after one trial for ignition if main burner fails to ignite
- Reset from thermostat after lockout
- Use modules with any combination gas control designed for direct spark applications and rated 2 amp or less
,
Item#:
G565-36
Manufacturer Item:
S87D1004
Manufacturer:
HONEYWELL
Sealed Unit Parts Q104 Double Stack Electric Sequencer
sealed unit parts q104
ICM Controls ICM292 DSI Furnace Control Board, 115 VAC at 60 Hz, 5-3/4Sid Harvey Item #:ICM292: Replaces Part #:'s : 62-24140-04,
,
,
Resideo ST9120U1011 Universal Electronic Fan Timer For Control of Combustion Blower for a Gas Warm Air Appliances, 18 - 30 VAC
,
- Replaces 40+ existing Resideo electronic fan timers
- Instruction sheet supplies full cross reference and wiring guide
- Interface harnesses for simple conversion
- Dip switch selectable heat and cool delay on and off times
- Electronic air cleaner and humidifier terminal connections
- Continuous low speed indoor air circulation
- Integrates control of all combustion blower and circulating fan operations in gas warm-air appliance
- Replaceable fuse
- Heat fan on delay - adjustable 30, 60 sec ( set at 30 sec)
- Heat fan off delay - adjustable 60, 120, 150, 180 sec (set at 120 sec)
- Cool fan on delay - adjustable 4, 30 sec (set at 4 sec)
- Cool fan off delay - adjustable 30, 60 sec (set at 30 sec)
,
Item#:
ST9120U1011
Manufacturer Item:
ST9120U1011
Manufacturer:
HONEYWELL
Cam-Stat L597BA Fan and Limit Control with Time Delay & Shield,
,
,
ICM Controls ICM272C Fan Blower Control Replacement for OEM models including Carrier HK61GA001/003,
,
,
ICM Controls ICM277 Control Board, 18 - 30 VAC , 20 amp Normally Open/10 amp Normally Closed
,
- Micro-processor-based fan blower
- Direct replacement for Goodman 800442010359/B1370735S/PCBFM131S
,