S2K Commerce - Products Dropdown
ActionsS2K Commerce - Shopping Cart
ActionsS2K Commerce - Order Entry
ActionsBrand Name
Brand Name
Type
Type
Container Size
Diameter
Voltage
Field Controls Motor Assembly Base, for Use With GVD Vent Damper Motor, Plastic
,
,
U. S. Boiler 6111714 Inducer Fan Blower Assembly For 203-204Pv And In3-In4Pv Boilers,
,
,
Item#:
6111714
Manufacturer Item:
6111714
Manufacturer:
U.S. BOILER COMPANY INC.
Tjernlund 950-0030 Inlet Collar Stainless Steel SS2
Item#:
950-0030
Manufacturer Item:
950-0030
Manufacturer:
TJERNLUND PRODUCTS INC
Field Controls 46234800 Stainless Steel Universal Replacement Fan and Motor Assembly
,
- Includes replacement motor and blower wheel on mounting bracket (46275900 motor and 46310400 wheel), adapter plate (for SWG models), mounting fasteners, blower wheel depth gage, 1/8" hex wrench, tube of high temperature silicone sealant, instruction sheet
,
Juniper Draftostat DR05 Regulator for Proper Operation of Oil Boilers, 5"
,
,
Juniper DR06 Draftostat Regulator for Proper Operation of Oil Boilers, 6"
,
,
Juniper Draftostat DR07 Regulator for Proper Operation of Oil Boilers, 7"
,
,
Juniper 8INDOS Oil Draftostat 8",
,
,
The ZD is a power close and spring open damper. It has a 24-volt motor used to control circulating air in HVAC systems and used when a normally-open damper is required. The ZD is typically used with the TrueZONE and other electronic zoning systems.
- Mechanical visual position indicator for damper status
- Solid construction using extruded aluminum frame and blades
- Parallel blade design for low leakage performance
- Simple, easy-to wire, two wire installation with a third wire option M4 for LED open only light
- Reliable, strong, 24 volt spring return motor
- Fail-safe, normally open operation
- Ordering instructions: order ZD (dimensions 1) x (dimensions 2), (motor is always mounted on dimensions 2 side) for example, ZD10x8 is a 10 x 8 Inch damper with the motor on the 8 Inch side, but a ZD8x10 is an 8 x 10 Inch damper that has the motor on the 10 Inch side
- Damper can be installed in any orientation (mounting side can be on either the bottom or the side of the duct)
- Motor or actuators mounting - side or top
- 30 sec power closed/10 sec spring return
- 90 deg angular rotation Honeywell Home TrueZone ZD Residential Damper, 10 x 12 Inch, Rectangular, 24 VAC, 0.32 amp, 90 deg Rotation, Import,
,
Item#:
ZD10X12TZ
Manufacturer Item:
ZD10X12TZ
Manufacturer:
HONEYWELL
Gas and oil heating appliances generate heat through the combustion of fuel. The heat is transferred through the heat exchanger and distributed to the conditioned space. The products of combustion, however, must be vented safely out of the structure. In a conventional chimney, venting is achieved by the natural lifting action of the hot combustion gas. New, efficient systems absorb more of the heat in the heat exchanger and produce lower temperature vent gas. Lower temperature gas does not rise as quickly or as reliably as in older, less efficient systems. Power venting or sidewall venting is more economical and safer than chimney venting. A power venter uses a motorized blower to vent the products of combustion. A power venter is interlocked with the appliance to ensure that proper draft is achieved before the appliance burner is activated.
,
- 100% negative pressure in the vent pipe for maximum safety
- Standard Galvanized pipe can be used instead of expensive stainless steel
- No need to seal vent pipe joints, saving time and money
- Significantly longer vent lengths than positive pressure, direct vent systems
- The SWG recommended by major heating appliance
- Thermal protected
- Power vent and backing plate included
,
Field Controls SWG-4HDS Stainless Steel Power Venter, 4", 115 VAC at 60 Hz, 1.7 amp, 138 watt The safest, most efficient power venter available today. Gas and oil heating appliances generate heat through the combustion of fuel. The heat is transferred through the heat exchanger and distributed to the conditioned space. The products of combustion, however, must be vented safely out of the structure. In a conventional chimney, venting is achieved by the natural lifting action of the hot combustion gas. New, efficient systems absorb more of the heat in the heat exchanger and produce lower temperature vent gas. Lower temperature gas does not rise as quickly or as reliably as in older, less efficient systems. Power venting or sidewall venting is more economical and safer than chimney venting. A power venter uses a motorized blower to vent the products of combustion. A power venter is interlocked with the appliance to ensure that proper draft is achieved before the appliance burner is activated.
- 100% negative pressure in the vent pipe for maximum safety
- Standard Galvanized pipe can be used instead of expensive stainless steel
- No need to seal vent pipe joints, saving time and money
- Significantly longer vent lengths than positive pressure, direct vent systems
- The SWG is recommended by major heating appliance manufacturers
- Thermal protected The safest, most efficient power venter available today. Gas and oil heating appliances generate heat through the combustion of fuel. The heat is transferred through the heat exchanger and distributed to the conditioned space. The products of combustion, however, must be vented safely out of the structure. In a conventional chimney, venting is achieved by the natural lifting action of the hot combustion gas. New, efficient systems absorb more of the heat in the heat exchanger and produce lower temperature vent gas. Lower temperature gas does not rise as quickly or as reliably as in older, less efficient systems. Power venting or sidewall venting is more economical and safer than chimney venting. A power venter uses a motorized blower to vent the products of combustion. A power venter is interlocked with the appliance to ensure that proper draft is achieved before the appliance burner is activated.Sid Harvey Item #:SWG-4HDS: Replaces Part #:'s : x89-857,
,Field Controls SWG-4HDS
Gas and oil heating appliances generate heat through the combustion of fuel. The heat is transferred through the heat exchanger and distributed to the conditioned space. The products of combustion, however, must be vented safely out of the structure. In a conventional chimney, venting is achieved by the natural lifting action of the hot combustion gas. New, efficient systems absorb more of the heat in the heat exchanger and produce lower temperature vent gas. Lower temperature gas does not rise as quickly or as reliably as in older, less efficient systems. Power venting or sidewall venting is more economical and safer than chimney venting. A power venter uses a motorized blower to vent the products of combustion. A power venter is interlocked with the appliance to ensure that proper draft is achieved before the appliance burner is activated.
,
- 100% negative pressure in the vent pipe for maximum safety
- Standard Galvanized pipe can be used instead of expensive stainless steel
- No need to seal vent pipe joints, saving time and money
- Significantly longer vent lengths than positive pressure, direct vent systems
- The SWG recommended by major heating appliance
- Thermal protected
- Power vent and backing plate included
,