Brand Name
Type
Diameter
Voltage
|◀ 25 - 36 of 81 ▶|
View:
Tjernlund 46235000 Stainless Steel Universal Replacement Motor Assembly, 6"
  • Field Controls 46235000 Stainless Steel Universal Replacement Motor Assembly, 6",
    ,



    Tjernlund SS2

Item#:
SWGII-6RMK
Manufacturer Item:
46235000
Manufacturer:
FIELD CONTROLS LLC
Gas and oil heating appliances generate heat through the combustion of fuel. The heat is transferred through the heat exchanger and distributed to the conditioned space. The products of combustion, however, must be vented safely out of the structure. In a conventional chimney, venting is achieved by the natural lifting action of the hot combustion gas. New, efficient systems absorb more of the heat in the heat exchanger and produce lower temperature vent gas. Lower temperature gas does not rise as quickly or as reliably as in older, less efficient systems. Power venting or sidewall venting is more economical and safer than chimney venting. A power venter uses a motorized blower to vent the products of combustion. A power venter is interlocked with the appliance to ensure that proper draft is achieved before the appliance burner is activated.
  • 100% negative pressure in the vent pipe for maximum safety
  • Standard Galvanized pipe can be used instead of expensive stainless steel
  • No need to seal vent pipe joints, saving time and money
  • Significantly longer vent lengths than positive pressure, direct vent systems
  • The SWG recommended by major heating appliance
  • Thermal protected
  • Power vent and backing plate included
,
,



Field Controls SWG-4HDS

Item#:
SWGII-4HD
Manufacturer Item:
46275400
Manufacturer:
FIELD CONTROLS LLC
Field Controls SWGII-6 Power Venter 6" 115 VAC,
,



Field Controls SWGII-5S

Item#:
SWGII-6
Manufacturer Item:
46234300
Manufacturer:
FIELD CONTROLS LLC
Gas and oil heating appliances generate heat through the combustion of fuel. The heat is transferred through the heat exchanger and distributed to the conditioned space. The products of combustion, however, must be vented safely out of the structure. In a conventional chimney, venting is achieved by the natural lifting action of the hot combustion gas. New, efficient systems absorb more of the heat in the heat exchanger and produce lower temperature vent gas. Lower temperature gas does not rise as quickly or as reliably as in older, less efficient systems. Power venting or sidewall venting is more economical and safer than chimney venting. A power venter uses a motorized blower to vent the products of combustion. A power venter is interlocked with the appliance to ensure that proper draft is achieved before the appliance burner is activated.
  • 100% negative pressure in the vent pipe for maximum safety
  • Standard Galvanized pipe can be used instead of expensive stainless steel
  • No need to seal vent pipe joints, saving time and money
  • Significantly longer vent lengths than positive pressure, direct vent systems
  • The SWG recommended by major heating appliance
  • Thermal protected
  • Power vent and backing plate included
Sid Harvey Item #:SWGII-5: Replaces Part #:'s : 39968,
,



Field Controls SWGII-4HD

Item#:
SWGII-5
Manufacturer Item:
46230000
Manufacturer:
FIELD CONTROLS LLC
Field Controls SWG-4HDS Stainless Steel Power Venter, 4", 115 VAC at 60 Hz, 1.7 amp, 138 watt The safest, most efficient power venter available today. Gas and oil heating appliances generate heat through the combustion of fuel. The heat is transferred through the heat exchanger and distributed to the conditioned space. The products of combustion, however, must be vented safely out of the structure. In a conventional chimney, venting is achieved by the natural lifting action of the hot combustion gas. New, efficient systems absorb more of the heat in the heat exchanger and produce lower temperature vent gas. Lower temperature gas does not rise as quickly or as reliably as in older, less efficient systems. Power venting or sidewall venting is more economical and safer than chimney venting. A power venter uses a motorized blower to vent the products of combustion. A power venter is interlocked with the appliance to ensure that proper draft is achieved before the appliance burner is activated.
  • 100% negative pressure in the vent pipe for maximum safety
  • Standard Galvanized pipe can be used instead of expensive stainless steel
  • No need to seal vent pipe joints, saving time and money
  • Significantly longer vent lengths than positive pressure, direct vent systems
  • The SWG is recommended by major heating appliance manufacturers
  • Thermal protected The safest, most efficient power venter available today. Gas and oil heating appliances generate heat through the combustion of fuel. The heat is transferred through the heat exchanger and distributed to the conditioned space. The products of combustion, however, must be vented safely out of the structure. In a conventional chimney, venting is achieved by the natural lifting action of the hot combustion gas. New, efficient systems absorb more of the heat in the heat exchanger and produce lower temperature vent gas. Lower temperature gas does not rise as quickly or as reliably as in older, less efficient systems. Power venting or sidewall venting is more economical and safer than chimney venting. A power venter uses a motorized blower to vent the products of combustion. A power venter is interlocked with the appliance to ensure that proper draft is achieved before the appliance burner is activated.Sid Harvey Item #:SWG-4HDS: Replaces Part #:'s : x89-857,
    ,



    Field Controls MG1-5

Item#:
SWG-4HDS
Manufacturer Item:
46395401
Manufacturer:
FIELD CONTROLS LLC
Field Controls SWGII-5S Power Venter 5" 115 VAC 3k RPM 290k Btu Stainless Steel,
,



Field Controls SWGII-5

Item#:
SWGII-5S
Manufacturer Item:
46395402
Manufacturer:
FIELD CONTROLS LLC
A double-acting control for gas-fired furnaces and boilers is widely used for conversion burner installations, gas draft-induced appliance operation with mechanical draft inducers, or sidewall power venters. It is also recommended for use on gas atmospheric appliances where a draft hood cannot be installed, and can improve combustion stability and draft on many gas atmospheric installations with venting problems. The MG-1 provides precise, accurate control of drafts at levels higher than permitted by a standard draft diverter, which is a frequent requirement with gas.
,
,



Field Controls 100-10

Item#:
100-11
Manufacturer Item:
MG-1-7
Manufacturer:
FIELD CONTROLS LLC
Field Controls 02724001 Silver Barometric Draft Control for Gas-Fired Furnaces and Boilers is Widely Used for Conversion Burner Installations, Gas Atmospheric Appliances, 6"
  • 28.3 sq-inch capacity
  • 5 - 6" pipe size
  • 24 ga (ring and gate), 26 ga (collar) thickness
  • Because it is double acting, it opens out to relieve positive vent system pressures as low as 0.01"
  • Can improve combustion stability and draft on many gas atmospheric installations with venting problems
  • Provides precise, accurate control of drafts at levels higher than permitted by a standard draft diverter
Sid Harvey Item #:100-10: Replaces Part #:'s : 40573,
,



Field Controls 100

Item#:
100-10
Manufacturer Item:
02724001
Manufacturer:
FIELD CONTROLS LLC
Tjernlund DJ-3 In-line Induced Draft Blower for Smokepipe and Aids Proper Exhaust of Combustion Gas, 115 VAC , 1/70 HP, 1550 RPM
  • Thermal protected
  • Aluminized steel blower wheel
Sid Harvey Item #:106: Replaces Part #:'s : 17140,
,



Tjernlund 100-12

Item#:
106
Manufacturer Item:
DJ-3
Manufacturer:
TJERNLUND PRODUCTS INC
Tjernlund D-3 Aluminized Steel Housing Inline Draft Inducer, 115 VAC, 0.96 amp, 1550 RPM, 1/20 HP
  • Venturi action starts air moving up the stack instantly and keeps it moving smoothly
  • In-line inducers are built for long-lasting, trouble-free service
  • Vari-draft control permits adjustment to individual job requirements
  • Vents/chimneys utilizing in-line draft inducers must be vertically terminated above the roof line
  • Solves venting problems: Undersized chimneys, negative pressures, long horizontal vent connectors, down drafts, cold equipment starts, restrictive heat exchangers/combustion chambers
  • 1 year warranty Tjernlund D-3 Aluminized Steel Housing Inline Draft Inducer, 115 VAC, 0.96 amp, 1550 RPM, 1/20 HPSid Harvey Item #:106-1: Replaces Part #:'s : x89-444,

    ,



    Tjernlund 106

Item#:
106-1
Manufacturer Item:
D-3
Manufacturer:
TJERNLUND PRODUCTS INC
Tjernlund I Inline Draft Inducer, 115 VAC , 1/4 HP, 1725 RPM
,
,



Tjernlund 106-10

Item#:
106-2
Manufacturer Item:
I
Manufacturer:
TJERNLUND PRODUCTS INC
Tjernlund Specially designed to terminate Tjernlund Side Wall Vent Systems. They are also an approved method of terminating many horizontally vented appliances. Vent hoods feature heavy duty, corrosion resistant aluminum construction. Models VH1-3, 4 and 6 also have an additional heat shield for built in clearances from combustibles. Building exteriors are kept clean while the aesthetics of the structure remain undisturbed. All mounting hardware is included.
  • 8" square rough-in
  • Mounting hardware
Sid Harvey Item #:106-20: Replaces Part #:'s : x89-442,
,



Tjernlund 106-2

Item#:
106-20
Manufacturer Item:
VH1-4
Manufacturer:
TJERNLUND PRODUCTS INC
|◀ 25 - 36 of 81 ▶|
View: