Field Controls CK-63 Control Kit for SWG Series Power Vent Hoods for Controlling Oil-fired Heating Appliances
  • Control the operation of SWG/CV power venter
  • Draft proving switch and secondary safety switch
  • Adjustable electronic post-purge
  • Includes mounted pressure switch and solid state post-purge control, (1) 2 feet length of 1/4" aluminum tubing, (1) 1/4" tubing connector, (1) flexible conduit connector, (1) WMO-1 secondary safety switch
Sid Harvey Item #:CK-63: Replaces Part #:'s : x71-291,
,


Field Controls CK-63

Item#:
CK-63
Manufacturer Item:
46399363
Manufacturer:
FIELD CONTROLS LLC
Field Controls 46139943 Control Kit with Adjustable Post Purge and Draft Control for SWG Power Venter, 24 VAC
,
,


Field Controls CK-43

Item#:
CK-43
Manufacturer Item:
46139943
Manufacturer:
FIELD CONTROLS LLC
Field Controls DI-1 Draft Inducer Blower, 115 VAC , 0.43 amp, 1550 RPM
  • Field draft inducers solve the drafting problems caused by short chimneys, undersized vent pipes and negative building pressures
  • Draft Inducers are designed for easy installation in a wide variety of applications, including oil or gas-fired furnaces, water heaters and boilers
  • For venting single or multiple appliances, use a control kit
,
,


Field Controls DI-1

Item#:
DI-1
Manufacturer Item:
46073000
Manufacturer:
FIELD CONTROLS LLC
Field Controls DI-3 Draft Inducer Motor 115V 1725 RPM 8"-12" Pipe,
,

Item#:
DI-3
Manufacturer Item:
46090700
Manufacturer:
FIELD CONTROLS LLC
Field Controls (GVD) gas vent damper was developed to reduce off cycle venting losses through boilers and draft hoods. When the boiler is in a standby mode, heat escapes up the chimney. The heat comes from the boiler and the conditioned space. To significantly reduce these losses, install a Field Controls Gas Vent Damper. The damper is installed in the vent as close to the draft hood as practical. When properly installed, the damper opens before the burner fires, and closes after the burner shuts off. The electrical circuits in this product are designed not to override the existing limit and safety controls of the boiler.
  • Operates with all 24 VAC , 60 Hz intermittent ignition and standing pilot ignition systems
  • Stainless steel construction provides superior corrosion resistance
  • Damper operation - power opens in 15 sec, power closes in 15 sec, power is off at damper motor when it is at rest
  • Hold open switch allows damper to be placed in an open position and taken out of service to assist with trouble shooting appliance problems
  • Keyed wiring harness connector plug installs only one way, preventing incorrect wiring connection
  • Flex seal provides self cleaning action
,
,


Field Controls GVD-5PL

Item#:
GVD-5PL
Manufacturer Item:
GVD-5
Manufacturer:
FIELD CONTROLS LLC
Field Controls (GVD) gas vent damper was developed to reduce off cycle venting losses through boilers and draft hoods. When the boiler is in a standby mode, heat escapes up the chimney. The heat comes from the boiler and the conditioned space. To significantly reduce these losses, install a Field Controls Gas Vent Damper. The damper is installed in the vent as close to the draft hood as practical. When properly installed, the damper opens before the burner fires, and closes after the burner shuts off. The electrical circuits in this product are designed not to override the existing limit and safety controls of the boiler.
  • Operates with all 24 VAC , 60 Hz intermittent ignition and standing pilot ignition systems
  • Stainless steel construction provides superior corrosion resistance
  • Damper operation - power opens in 15 sec, power closes in 15 sec, power is off at damper motor when it is at rest
  • Hold open switch allows damper to be placed in an open position and taken out of service to assist with trouble shooting appliance problems
  • Keyed wiring harness connector plug installs only one way, preventing incorrect wiring connection
  • Flex seal provides self cleaning action
Item#:
GVD-8
Manufacturer Item:
46360001
Manufacturer:
FIELD CONTROLS LLC
Field Controls (GVD) gas vent damper was developed to reduce off cycle venting losses through boilers and draft hoods. When the boiler is in a standby mode, heat escapes up the chimney. The heat comes from the boiler and the conditioned space. To significantly reduce these losses, install a Field Controls Gas Vent Damper. The damper is installed in the vent as close to the draft hood as practical. When properly installed, the damper opens before the burner fires, and closes after the burner shuts off. The electrical circuits in this product are designed not to override the existing limit and safety controls of the boiler.
  • Operates with all 24 VAC , 60 Hz intermittent ignition and standing pilot ignition systems
  • Stainless steel construction provides superior corrosion resistance
  • Damper operation - power opens in 15 sec, power closes in 15 sec, power is off at damper motor when it is at rest
  • Hold open switch allows damper to be placed in an open position and taken out of service to assist with trouble shooting appliance problems
  • Keyed wiring harness connector plug installs only one way, preventing incorrect wiring connection
  • Flex seal provides self cleaning action
,
,


Field Controls GVD-4PL

Item#:
GVD-4PL
Manufacturer Item:
46486901
Manufacturer:
FIELD CONTROLS LLC
Field Controls (GVD) gas vent damper was developed to reduce off cycle venting losses through boilers and draft hoods. When the boiler is in a standby mode, heat escapes up the chimney. The heat comes from the boiler and the conditioned space. To significantly reduce these losses, install a Field Controls Gas Vent Damper. The damper is installed in the vent as close to the draft hood as practical. When properly installed, the damper opens before the burner fires, and closes after the burner shuts off. The electrical circuits in this product are designed not to override the existing limit and safety controls of the boiler.
  • Operates with all 24 VAC , 60 Hz intermittent ignition and standing pilot ignition systems
  • Stainless steel construction provides superior corrosion resistance
  • Damper operation - power opens in 15 sec, power closes in 15 sec, power is off at damper motor when it is at rest
  • Hold open switch allows damper to be placed in an open position and taken out of service to assist with trouble shooting appliance problems
  • Keyed wiring harness connector plug installs only one way, preventing incorrect wiring connection
  • Flex seal provides self cleaning action
Sid Harvey Item #:GVD-6PL: Replaces Part #:'s : 40703,
,


Field Controls GVD-6PL

Item#:
GVD-6PL
Manufacturer Item:
46487101
Manufacturer:
FIELD CONTROLS LLC
Field Controls (GVD) gas vent damper was developed to reduce off cycle venting losses through boilers and draft hoods. When the boiler is in a standby mode, heat escapes up the chimney. The heat comes from the boiler and the conditioned space. To significantly reduce these losses, install a Field Controls Gas Vent Damper. The damper is installed in the vent as close to the draft hood as practical. When properly installed, the damper opens before the burner fires, and closes after the burner shuts off. The electrical circuits in this product are designed not to override the existing limit and safety controls of the boiler.
  • Operates with all 24 VAC , 60 Hz intermittent ignition and standing pilot ignition systems
  • Stainless steel construction provides superior corrosion resistance
  • Damper operation - power opens in 15 sec, power closes in 15 sec, power is off at damper motor when it is at rest
  • Hold open switch allows damper to be placed in an open position and taken out of service to assist with trouble shooting appliance problems
  • Keyed wiring harness connector plug installs only one way, preventing incorrect wiring connection
  • Flex seal provides self cleaning action

    Field Controls GVD-7PL

Item#:
GVD-7PL
Manufacturer Item:
46487201
Manufacturer:
FIELD CONTROLS LLC
Tjernlund HS1 Steel Side Wall Power Venter with UC1 Control, 115 VAC at 60 Used for side wall venting residential/light commercial natural gas, LP or oil fired equipment including: Furnaces, boilers, water heaters and unit heaters. All models feature the new UC1 universal control and a diaphragm fan proving switch safety interlock which will shut down the heating equipment if a venting malfunction occurs. Built-in adjustable damper also allows regulation for maximum combustion efficiency. UC1 universal control features include, adjustable pre and post-purge settings, LED status/diagnostic indicators, fan prover switch monitoring. Interlocks with any 24 - 120 VAC burner control circuit and also includes dry contact actuation option. Easily interlock multiple appliances with our MAC-series multiple appliance controls.Sid Harvey Item #:HS1: Replaces Part #:'s : 21767,

,


Tjernlund HS1

Item#:
HS1
Manufacturer Item:
HS-1
Manufacturer:
TJERNLUND PRODUCTS INC
Tjernlund HS2 Aluminized Steel Housing and Blower Wheel Side Wall Power Venter, 6", 115 VAC , 3300 RPM , 600000 BTU
  • UC1 universal control and a diaphragm fan proving switch safety interlock which will shut down the heating equipment if a venting malfunction occurs
  • Built-in adjustable damper also allows regulation for maximum combustion efficiency
  • Interlocks with any 24/120 VAC burner circuit
  • UC1 universal control features adjustable pre/post-purge, LED status indicators, and fault code memory
  • Thermal protection, sintered iron sleeve type bearing
  • UC1 interlock control, fan proving switch, adjustable damper, vibration isolators included
Sid Harvey Item #:HS2: Replaces Part #:'s : 30933,
,


Tjernlund HS2

Item#:
HS2
Manufacturer Item:
HS2
Manufacturer:
TJERNLUND PRODUCTS INC
A double-acting control for gas-fired furnaces and boilers is widely used for conversion burner installations, gas draft-induced appliance operation with mechanical draft inducers or sidewall power venters. It is also recommended for use on gas atmospheric appliances where a draft hood cannot be installed and can improve combustion stability and draft on many gas atmospheric installations with venting problems. The MG-1 provides precise, accurate control of drafts at levels higher than permitted by a standard draft diverter, which is a frequent requirement with gas. Because it is double-acting, it opens out to relieve positive vent system pressures as low as 0.01" draft adjustments using weights are simple and accurate from 0.01 - 0.1".
,
,


Field Controls MG1-5

Item#:
MG1-5
Manufacturer Item:
46210701
Manufacturer:
FIELD CONTROLS LLC