S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Brand Name
Type
Inlet Size
Outlet Size
Pressure Setting
Taco 49-150C-2 Automatic Air Separator, 1-1/2", Sweat, 150 psig, 25 - 240 deg F, 49 Cv, 5 fps Maximum, 42 kilo-VAC, Brass, 5-7/16" W x 7-9/16" H
- 42 kilo-VAC rating
- Removes unwanted air from closed loop heating and cooling systems to help increase efficiency and eliminate noise
- Water or water/glycol media
- Features bi-directional flow, patented pall ring design
- Minimal pressure loss, vent can be closed
- Large surface contact area, protective vent plate
- Rugged dependability, maximum air removal
- Convenient expansion tank connection tapping, bi-directional flow
- Stainless steel pall rings
- Stainless steel, EPDM, viTon, brass and engineered plastics venting unit components
Taco 49-150C-2
Viessmann Parts 7819971 Air Vent 3/8",
Viessmann Heating Parts 7819971
Item#:
7819971
Manufacturer Item:
7819971
Manufacturer:
VIESSMANN MANUFACTURING INC.
Webstone Valve 74005 Air Separator 1-1/4" FPT
Webstone Valve 74005
Bell & Gossett 112113 EASB-1-1/4 JR Enhanced Air Separator, 1-1/4", NPT, 150 psi, 250 deg F, Brass, 4-5/8" W x 7-1/2" H
- Automatically removes entrained air bubbles in hydronic system
- Stainless steel cOverall Lengthescing medium, non ferrous venting mechanism
Bell & Gossett 112113
Item#:
112113
Manufacturer Item:
112113
Manufacturer:
BELL & GOSSETT ITT
Altherm 21790 Temperature and Pressure Relief Valve
- 3/4"
- 51E
- 150 psi,
Bock 21790
Item#:
21790
Manufacturer Item:
21790
Manufacturer:
BOCK WATER HEATERS
Apollo Valves FFS12 Bronze Fast Fill Water Feeder Pressure Regulator, 1/2" Solder Union x FNPT
- The Apollo model FF fast fill or feed water pressure regulator provides the heating boiler with make up water at reduced inlet pressure with a high capacity purge or quick fill capability
- ASTM grade materials for corrosion resistance and long life, cartridge is replaceable in-line
- All brass/bronze construction
- 100% factory tested and preset to 15 psi pressure
- Integral check and stainless steel strainer
- ASTM B16 brass adjustment screw, zinc plated spring steel, ASTM B584 bronze cage/body, steel and zinc plated lever, nitrile check seat/seat washer, nitrile/nylon diaphragm
Apollo Valves 3570301
Item#:
3570301
Manufacturer Item:
FFS12
Manufacturer:
CONBRACO INDUSTRIES INC
Taco Flo-Checks prevent gravity circulation in forced hot water heating systems during periods when the boiler is hot, but the space heating zone is not wanted. This makes it possible to use the heating boiler to maintain domestic hot water year-round. You can also use Flo-Checks in systems with multiple circulator zones to allow heat to flow only into the zones that are calling for heat. In addition, the thumb screw can be opened manually for gravity feed applications, if the main circulator stops operating.
- In systems with multiple circulator zones to allow heat to flow only into the zones that are calling for heat
- Feature a thumb screw to manually open the valve and are available in a cast iron universal body and a bronze sweat in-line configuration
- The thumb screw can be opened manually for gravity feed applications, if the main circulator stops operating
- Open automatically when the circulator starts running, when the room thermostat is satisfied and the circulator is stopped, the flo-checks close immediately, preventing gravity circulation
- Water or glycol media
Taco B146-22
Item#:
B146-22
Manufacturer Item:
221-6
Manufacturer:
TACO INC.
Taco flo-cheks have dependably stopped gravity circulation in forced hot water heating systems for over 40 years. Flo-cheks open automatically when the circulator starts running. They feature a thumb screw to manually open the valve and are available in a cast iron universal body and a bronze sweat in-line configuration.
- Flo-cheks allow heat to flow only into the zones that are calling for heat
- Thumb screw can be manually opened for gravity feed applications if the main circulator stops operating
- Taco flo-cheks open automatically when the circulator starts running
Taco B146-20
Item#:
B146-20
Manufacturer Item:
218-3
Manufacturer:
TACO INC.
Taco Flo-Checks prevent gravity circulation in forced hot water heating systems during periods when the boiler is hot, but the space heating zone is not wanted. This makes it possible to use the heating boiler to maintain domestic hot water year-round. You can also use Flo-Checks in systems with multiple circulator zones to allow heat to flow only into the zones that are calling for heat. In addition, the thumb screw can be opened manually for gravity feed applications, if the main circulator stops operating.
- In systems with multiple circulator zones to allow heat to flow only into the zones that are calling for heat
- Feature a thumb screw to manually open the valve and are available in a cast iron universal body and a bronze sweat in-line configuration
- The thumb screw can be opened manually for gravity feed applications, if the main circulator stops operating
- Open automatically when the circulator starts running, when the room thermostat is satisfied and the circulator is stopped, the flo-checks close immediately, preventing gravity circulation
- Water or glycol media
Taco B146-21
Item#:
B146-21
Manufacturer Item:
220-6
Manufacturer:
TACO INC.
Taco flo-cheks have dependably stopped gravity circulation in forced hot water heating systems for over 40 years. Flo-cheks open automatically when the circulator starts running. They feature a thumb screw to manually open the valve and are available in a cast iron universal body and a bronze sweat in-line configuration.
- Flo-cheks allow heat to flow only into the zones that are calling for heat
- Thumb screw can be manually opened for gravity feed applications if the main circulator stops operating
- Taco flo-cheks open automatically when the circulator starts running
Taco B146-19
Item#:
B146-19
Manufacturer Item:
219-4
Manufacturer:
TACO INC.
Bell & Gossett 107035
The Hydrotrol (HT) flow control valve is used to prevent overheating of zones due to gravity flow in hydronic heating systems and will permit summer-winter operation of indirect water heater. The HT valve allows fluid to pass when the system or zone pumps start. When the system or zone pumps are not operating, the HT valve remains closed, preventing gravity circulation. The HT valves are designed with a 1/2 turn knob that can be manually opened when draining the system or for bypass purposes. The HT valve can be installed in either the horizontal or vertical orientation.
The Hydrotrol (HT) flow control valve is used to prevent overheating of zones due to gravity flow in hydronic heating systems and will permit summer-winter operation of indirect water heater. The HT valve allows fluid to pass when the system or zone pumps start. When the system or zone pumps are not operating, the HT valve remains closed, preventing gravity circulation. The HT valves are designed with a 1/2 turn knob that can be manually opened when draining the system or for bypass purposes. The HT valve can be installed in either the horizontal or vertical orientation.
- Prevents rooms (zones) from overheating due to gravity circulation
- Elastomer seal provides positive, shut-off eliminating the need for an isolation valve
- Brass body and non-ferrous internals
- Straight angle configuration allows for quick and easy installation
- Vertical design option saves installation time and material
- Turn knob for system draining or valve bypass
- Compact, lightweight design
Bell & Gossett 107035