S2K Commerce - Products Dropdown
ActionsS2K Commerce - Shopping Cart
ActionsS2K Commerce - Order Entry
ActionsRemanufactured products are available only with exchange for similar defective units. All products will be assessed a CORE Charge until exchange is completed.
What is a core Charge?
- CORE Charges vary by product.
- All Remanufactured items purchased will be assessed a CORE CHARGE at invoice based on product.
- CORE CHARGES will be refunded when CORES are dropped off at store location or pickup arrangements are pre-arranged.
- Bulk CORE pickups must be coordinated with local store managers or Sid Harvey Corporate Office.
Sid Harvey Honeywell L8124A High and Low Limit Circulator Triple Aquastat Relay, 120 VAC, 130 - 240 deg F Adjustable High Limit, 110 - 220 deg F Adjustable Low Limit
,
- Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Select models include large transformers and extra terminals for supplying power to low voltage zone valves
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
,
Item#:
C317-2R
Manufacturer Item:
L8124A1007,1015,1098
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured R80-52R Protectorelay & Hydronic Heating Controller for Oil Hydronic System REMANUFACTURED,
,
,
Item#:
R80-52R
Manufacturer Item:
R8182E
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey R80-58R Combination Protectorelay and Hydronic Heating Controller, 120 VAC, 4.4 amp Full Load, 26.4 amp Locked Rotor Burner at 120 VAC, 9 watt, Remanufactured
- Immersion type aquastat controller and oil burner primary control provides high limit and low limit/circulator control for oil-fired hydronic heating systems
- Use in intermittent ignition applications
- Capable of zone control with zone valves
- Circulator zone control with ZC and ZR terminals on R8182D, E, H, J
- 8-flame failure during the running cycle results in a 45 sec attempt to restart
- If unsuccessful, safety shutoff occurs, requiring manual reset before burner can be restarted
- C554A cadmium sulfide flame detector and a 24 VAC thermostat required
- Includes auxiliary ZC and ZR terminals may be used to provide circulator zone control through an R845A switching relay, horizontal case
- Maximum 250 deg F at element, 15 deg F fixed high limit differential temperature
- 45 sec safety switch timing
- 1/2"-14 NPT well spud size
- 0.2 amp anticipator setting
- 1-1/2" insulation depth,
,
Item#:
R80-58R
Manufacturer Item:
R8182J1059
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured R80-40R Combination Protectorelay 5' Remote Bulb REMANUFACTURED,
,
,
Item#:
R80-40R
Manufacturer Item:
R8182H1070
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured R80-30R Combination Protectorelay (W/Well Adapter) REMANUFACTURED,
,
,
Item#:
R80-30R
Manufacturer Item:
R8182D1079
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured R80-32R Control Relay Combination Control Horizontal REMANUFACTURED,
,
,
Item#:
R80-32R
Manufacturer Item:
R8182D1111
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured R75-41R Oil Burner Primary Control R8184G Plastic Box 15 Second REMANUFACTURED,
,
,
Item#:
R75-41R
Manufacturer Item:
R75-41R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell R8184G4074 Non-Recycle Oil Burner Control with Safety Timing, 120/220/240 VAC
,
- Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
- Solid state flame sensing circuit
- LED on terminal strip indicates system lockout
Remote lockout indication - Enclosed safety switch with external reset butTon
- Manual trip lever opens safety switch for system maintenance
- Mounts on standard 4 x 4" junction box
- C554A cadmium sulfide flame detector and 24 VAC thermostat required
- With 30 sec safety timing, alarm outputs and manual safety switch
,
Sid Harvey R75-61R 2-Wire CAD Cell Relay, 24 volt, Remanufactured
- Ignition comes on for duration of safety timing if flame fails during operationSid Harvey Item #:R75-61R: Replaces Part #:'s : R75-61R,
,
Item#:
R75-61R
Manufacturer Item:
R8404AA
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell R8184M Oil Burner Primary Control for C554A Cadmium Sulfide Cell and 24VAC Thermostat, 120/26.5 VAC , 9 amp
,
,
Sid Harvey Honeywell R8184G4009 Non-Recycle Oil Burner Control with Safety Timing, 120/220/240 VAC
,
- Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
- Solid state flame sensing circuit
- LED on terminal strip indicates system lockout
- Remote lockout indication
- Enclosed safety switch with external reset butTon
- Manual trip lever opens safety switch for system maintenance
- Mounts on standard 4 x 4" junction box
- C554A cadmium sulfide flame detector and 24 VAC thermostat required
- With 15 sec safety timing, alarm outputs and manual safety switch
,
Item#:
R75-40R
Manufacturer Item:
R8184G4009
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey B163-14R Power Head Assembly V8043E-B REMANUFACTURED,
,
,
Item#:
B163-14R
Manufacturer Item:
V8043E-B
Manufacturer:
SID HARVEY REMANUFACTURED