S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Brand Name
Part Type
Voltage
Contact Type
Max On/Off Cycles
Termination Type
Sealed Unit Parts UET240 Universal, Adjustable, Electronic Defrost Timer, 10 - 35 min
Sealed Unit Parts UET240
Paragon 8145-20M Steel Defrost Timer, 208/240 VAC , 4 - 110 min in 2 min The Paragon 8000 series commercial defrost controls are designed for commercial freezers and refrigerators to provide automatic defrost capability. They accommodate various types of defrost systems including electric defrost heaters, hot gas, and compressor off cycle
Paragon 8145-20M
Sealed Unit Parts SPG1401GE Plastic Heavy-Duty Defrost Timer, 120 volt, 15 amp
- Domestic refrigerators and freezers
- 6 hr cycle time
Sealed Unit Parts SPB1401F
Robertshaw Controls Paragon 8045-20 Mechanical Defrost Timer, 4 - 110 min, 208 - 240 VAC , 2 HP, SPDT, 1 Pole
Paragon C255-120
Robertshaw Controls C255-150 Mechanical Defrost Timer
- Time Initiated/Pressure Terminated 240 VAC SPDT
Robertshaw C255-150
Sealed Unit Parts C265 Universal Electronic Defrost Timer
- 1-35 Min Spdt 12 Vac 1 Amp Max 10 Amp
Sealed Unit Parts C265
Robertshaw Controls C255-136 Defrost Timer 240 VAC
Robertshaw C255-136
Robertshaw Controls Paragon 8000 Mechanical Defrost Timer, 4 - 110 min, 120 VAC , 2 HP, SPST, 1 Pole
Paragon C255-130
Robertshaw Controls Paragon 8145-20 Mechanical Defrost Timer, 4 - 110 min, 208 - 240 VAC , 2 HP, SPDT, 1 Pole
Paragon C255-140
Paragon 8041-00 Heavy-Duty Steel Enclosure Mechanical Defrost Timer
Paragon C255-110
Paragon 8141-20 Heavy-Duty Steel Enclosure Mechanical Defrost Control For
Paragon C255-132
The Paragon 8000 series commercial defrost controls are designed for commercial freezers and refrigerators to provide automatic defrost capability. They accommodate various types of defrost systems including electric defrost heaters, hot gas, and compressor off cycle.
- Positive slide bar switch design assures positive electrical contact and wipes the contact surface of contaminates
- Temperature or pressure terminated models are designed to stop defrosting using an external temperature or pressure device
- Safety back-up - mechanical time-driven defrost termination
- Heavy-duty synchronous design drive motor
- Choice of 3-contact arrangements
- Adjustable frequency of defrost initiation from 1 - 6-cycles per day with a minimum of 4 hr between successive operations
- Adjustable back-up defrost termination from 4 - 110 min in 2 min increments
- Have an adjustable cut-in pressure dial calibrated from 36 - 110 lb for R12, R22, R502
- Time initiated/temperature or pressure terminated
- Open switch arrangement for contacts 1 - 3, closed switch arrangement for contacts 2 - 4
- Electric heat, hot gas or compressor shutdown
- 1 year limited warranty
Paragon C255-138