High performance multi-function hydraulic separator
The Caleffi SEP4 saves on system installation and maintenance costs with four high performance functions combined into one device: hydraulic separation, micro-bubble coalescing air separation, dirt separation and magnetic separation. Includes thermowell tap, pre-formed insulation jacket and easy-touse drain valve. Constructed of corrosion-resistant functional parts for a long, trouble free operating life.
The Caleffi SEP4 saves on system installation and maintenance costs with four high performance functions combined into one device: hydraulic separation, micro-bubble coalescing air separation, dirt separation and magnetic separation. Includes thermowell tap, pre-formed insulation jacket and easy-touse drain valve. Constructed of corrosion-resistant functional parts for a long, trouble free operating life.
Item#:
549566A
Manufacturer Item:
549566A
Manufacturer:
CALEFFI NORTH AMERICA, INC.
Caleffi 551066A Air Separator 1" PRESS DISCAL
Caleffi 551066A
Item#:
551066A
Manufacturer Item:
551066A
Manufacturer:
CALEFFI NORTH AMERICA, INC.
Bell & Gossett 112115 Air Eliminator 1" Sweat,
,
,
Item#:
112115
Manufacturer Item:
112115
Manufacturer:
BELL & GOSSETT ITT
Bell & Gossett Airtol ATF-12 Cast Iron Tank Fitting, 1/2", FNPT x FNPT Airtrol tank fittings help establish the proper initial liquid level in the compression tank when filling the hydronic system. They help maintain proper system pressurization by directing released air to the compression tank during system operation and permit cooler liquid flow to the boiler during the off cycle as system liquid cools. Airtrol tank fittings must be used with the appropriately sized in-line airtrol or rolairtrol air separator.
- Copper and copper plated tubes
- Brass vent tube fittings Airtrol tank fittings help establish the proper initial liquid level in the compression tank when filling the hydronic system. They help maintain proper system pressurization by directing released air to the compression tank during system operation and permit cooler liquid flow to the boiler during the off cycle as system liquid cools. Airtrol tank fittings must be used with the appropriately sized in-line airtrol or rolairtrol air separator.Sid Harvey Item #:ATF12: Replaces Part #:'s : 3651,
,
Bell & Gossett 79 Air Vent 3/4" x 1/2" 75Lb Max,
,
,
Gorton Heating Corp D18A #D Angle Air Vent Valve, 1/8", MNPT
,
- Non adjustment
,
Gorton Heating Corp C18A Steel #C Angle Air Vent Valve, 1/8", MNPT
,
- Non adjustment
,
GorTon Heating 418A Angle Steam Valve #4 1/8" MPT,
,
,
Steel Non-Adjustable #5 Angle Air Vent Valve 1/8" MNPT
,
- Non adjustment
- Install on radiators near the boiler and in warm rooms
- Venting capacity - equal to 4 ordinary type air valves
,
Honeywell L8124C1003 Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
,
- Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water service
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
- Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Electrical burner rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC line voltage; at locked rotor: 44.4 amp at 120 VAC, 22.7 amp at 240 VAC line voltage
- Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
- 1-1/2" depth insulation
,
Item#:
C317-5
Manufacturer Item:
L8124C1003
Manufacturer:
HONEYWELL
Aquastat controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. Honeywell's L4006 are used in applications that utilize the existing wells.
- Totally enclosed micro switch snap-acting switches operate on temperature rise to setpoint
- Visible control point scale and external adjustments screw permit easy setting
- Direct or well immersion of the sensing element
- Remote bulb model may be used to sense air temperature in ducts and in outside air sensing applications Honeywell L4006A2007 High or Low Limit Immersion Aquastat Controller, 100 - 240 deg F, 5 - 30 deg F DifferentialSid Harvey Item #:C290A: Replaces Part #:'s : AQU4006A1678-C290 | AQU4006A2007-C290A | C290 | C290R |,
,
Aquastat controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. Honeywell's L4006 are used in applications that utilize the existing wells.
,
- Totally enclosed micro switch snap acting switches operate on temperature rise to setpoint
- Visible control point scale and external adjustments screw permit easy setting
- Horizontal insertion of the sensing element
- Direct/well immersion of the sensing element
- Remote bulb model may be used to sense air temperature in ducts and in outside air sensing applications
- Contacts make on temperature rise
- Screw terminals wiring
,