View:
2-M Manual Reset Low Water Cutoff Switch 120/240 volt

McDonnell & Miller B115-1

Item#:
B115-1
Manufacturer Item:
110100
Manufacturer:
XYLEM INC.
Mcdonnell & Miller 47-2 Mechanical Water Feeder, 3/4" NPT Threaded, 120/240 VAC
    Continuous maintenance of minimum safe water level, independent of electrical service
  • Proportional feed action
  • Quick hook-up fittings provided
  • Quick change replaceable cartridge valve and strainer
  • Model 47 can be field upgraded with a No #2 switch to add low water cut-off function

    McDonnell & Miller B110-1

Item#:
B110-1
Manufacturer Item:
47-2
Manufacturer:
XYLEM INC.
Mcdonnell & Miller UniMatch WFE-120 Universal Electric Water Feeder, 3/8" NPT Threaded, 120 VAC
    Field-adjustable dwell-feed cycles
  • Multi color LED status indicator
  • Manual feed button
  • Hard-stop limit to minimize chances of flooding the boiler
  • Compatible with all electronic and mechanical low water cut-off
  • Includes adapters for connection to 1/2" copper tubing
  • Removable strainer

    McDonnell & Miller B112-7

Item#:
B112-7
Manufacturer Item:
WFE-120
Manufacturer:
XYLEM INC.
Programmable Water Feeder 10 Gallon 1/2" Sweat 120 VAC
    Universal compatibility
  • Digital feed counter
  • Programmable feed delay settings (30 sec - 10 min)
  • Programmable feed amount settings (LWCO and 1-5 Gallon)
  • Manual feed button
  • Underfeed protection
  • Lock-out flood protection

    Nordic Technology FAST-STAT5000

Item#:
B112-5
Manufacturer Item:
VXT-120
Manufacturer:
HYDROLEVEL COMPANY
Electric Water Feeder 24 volt 150 psi Maximum Water Supply 25 psi Maximum Boiler
    Eliminates necessity to manually add water to the boiler
  • Can be used with mechanical or electronic low water cut-off controls
  • Quick-change replaceable cartridge valve and strainer
  • Manual feed butTon
  • 40 VA transformer

    McDonnell & Miller B112-8

Item#:
B112-8
Manufacturer Item:
169500
Manufacturer:
XYLEM INC.
VxT-24 Automatic Low Water Cut-Off Water Feeder 15 psi Steam 150 psi Water 1/2" Sweat 24 VAC
    No more trips to the basement to add water to the boiler
  • Works with all probe and float type low water cut-offs
  • Brightly illuminated feed counter displays the amount of water added to the boiler
  • Built-in memory prevents power interruptions from clearing the counter
  • Helps prevent flooded boilers, allows time for condensate to return to the boiler before starting a feed cycle
  • Six settings provide two ways to feed
  • 1 - 5 Gallon settings now feed above the probe to restore the boiler's normal operating level or select LWCO setting to end the feed cycle
  • Allows for additional make-up water at the touch of a button, manual feed amounts are recorded and added to the totalGallons displayed by the feed counter
  • If one feed cycle is not sufficient to restore boiler operation, the VxT will delay and feed one additional cycle
  • Digital feed counter
  • 30 sec to 10 min programmable feed delay settings
  • LWCO and 1 - 5 Gallon programmable feed amount settings
  • Manual feed button
  • Underfeed protection
  • Lock-out flood protection
  • 1 gpm flow rate
  • 10 VA power consumption

    Hydrolevel B112-4

Item#:
B112-4
Manufacturer Item:
VXT-24
Manufacturer:
HYDROLEVEL COMPANY
Mcdonnell & Miller 369 Low Water Cut-Off, 120/240 VAC, 20 psi, Automatic Reset
    Adjustable Bx outlet for easy installation
  • Dual precision switches for dependable operation of cut-off, alarm or electric water feeder
  • Packless bellows
  • Millivolt circuits
Sid Harvey Item #:B106-4: Replaces Part #:'s : L38-768

McDonnell & Miller B106-4

Item#:
B106-4
Manufacturer Item:
155300
Manufacturer:
XYLEM INC.
Boiler Insert for Series 67 and 69 Low Water Cut-Off Boilers

McDonnell & Miller B120

Item#:
B120
Manufacturer Item:
153825
Manufacturer:
XYLEM INC.
Hydrolevel Safgard 450 Low Water Cut-Off, 120 VAC, 15 psi, Automatic Reset
    Burner circuit contacts open after 15 sec delay in a low water condition
  • Delay prevents short cycling caused by momentary fluctuations in the boiler water level
  • Automatically reactivates burner circuit 30 sec after water reaches the probe, allowing optional water feeder to raise water level above the probe
  • SPDT switch contact

    Hydrolevel B103-38

Item#:
B103-38
Manufacturer Item:
45-450
Manufacturer:
HYDROLEVEL COMPANY
Mcdonnell & Miller No. 2 Auto Reset Low Water Cutoff Alarm Switch, 120 - 240 VAC at 60 Hz

McDonnell & Miller B115

Item#:
B115
Manufacturer Item:
110000
Manufacturer:
XYLEM INC.
Hydrolevel Safgard 550 Low Water Cut-Off, 120 VAC, 250 psi, Manual Reset
    Provides step-by-step, diagrammed instructions for fast, easy installation and wiring
  • Burner circuit locks-out if water remains below probe for 30 sec
  • Burner circuit test butTon allows for testing the control without lowering the water level and indicator lights for easy troubleshooting
  • SPDT switch contact

    Hydrolevel B112-3

Item#:
B112-3
Manufacturer Item:
45-550
Manufacturer:
HYDROLEVEL COMPANY
Mcdonnell & Miller GuardDog 751P-MT-120 Electronic Low Water Cut-Off, 120 VAC, 15 psi Steam, 160 psi Water, Automatic Reset
  • No lock out with loss of power if probe is in water
  • Test butTon
  • Green LED indicates power on
  • Red LED indicates low water
  • 20000 ohm probe sensitivity
  • With standard probe
,
,


McDonnell & Miller B103-5

Item#:
B103-5
Manufacturer Item:
176234
Manufacturer: