Brand Name
Type
Pipe Size
Connection Type
Voltage
|◀ 37 - 48 of 123 ▶|
View:
Sid Harvey B163-11 Replacement Zone Valve Motor
,
,


Sid Harvey B163-11

Item#:
B163-11
Manufacturer Item:
B163-11
Manufacturer:
MITCO MFG.
Honeywell V8043F1036/U Brass 2-Way/2-Position Normally Closed Low VAC age Straight-Through Zone Valve, 3/4", Sweat
  • 2-way on-off low VAC age valves consist of an actuator and valve assembly for controlling the flow of hot water
  • Manual opener for valve operation on power failure, valve returns to automatic position when power is restored
  • All model may be installed without disassembling the valve
  • Compact construction for easy installation
  • Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
  • Actuator motor may be replaced without removing the valve body or draining the system
  • Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water
  • 15 sec nominal open timing
  • Screw terminal block electric connection
  • Spring return to close valve action
  • No SPST auxiliary end switch
  • 50 VA pilot duty at 24 VAC , 4.4 amp running with 26.4 amp inrush at 120 VAC end switch rating
  • Buna-N (NBR) rubber plug
  • Manual opener
Sid Harvey Item #:B163-5: Replaces Part #:'s : 12794,
,

HONEYWELL B163-5

Item#:
B163-5
Manufacturer Item:
V8043F1036
Manufacturer:
HONEYWELL
White Rodgers Cooling Controls F19-0097 3-Wire Motor Assembly for 3-Wire Zone Valves 1311-102, -103, -104
Sid Harvey Item #:B163-112: Replaces Part #:'s : 3C7193,

White Rodgers B163-112

Item#:
B163-112
Manufacturer Item:
F19-0097
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Honeywell V8043F1051/U Brass 2-Way/2-Position Normally Closed Low VAC age Straight-Through Zone Valve, 1", Sweat
  • 2-way on-off low VAC age valves consist of an actuator and valve assembly for controlling the flow of hot water
  • Manual opener for valve operation on power failure, valve returns to automatic position when power is restored
  • All model may be installed without disassembling the valve
  • Compact construction for easy installation
  • Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
  • Actuator motor may be replaced without removing the valve body or draining the system
  • Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water
  • 15 sec nominal open timing
  • Screw terminal block electric connection
  • Spring return to close valve action
  • No SPST auxiliary end switch
  • 50 VA pilot duty at 24 VAC , 4.4 amp running with 26.4 amp inrush at 120 VAC end switch rating
  • Buna-N (NBR) rubber plug
Sid Harvey Item #:B163-6: Replaces Part #:'s : 12795,

,



HONEYWELL B163-6

Item#:
B163-6
Manufacturer Item:
V8043F1051
Manufacturer:
HONEYWELL
White Rodgers Cooling Controls B163-108 2-Way 3-Wire Normally Closed Hydronic Zone Control Valve 1-1/4" Sweat,

Item#:
B163-108
Manufacturer Item:
1311-104
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Taco heat motor zone valves provide a time proven method for system zoning and control. The exclusive heat motor design operates silently, while the twist off head allows for serviceability without disturbing system connections.
  • Heat motor zone valves provide a convenient way to create individual zones or equipment isolation in a hydronic heating system
  • Using multiple heat motor zone valves and a single pump, you can start, stop or divert flow through the system to provide individual room or area comfort control and energy savings
  • Rugged dependability
  • Silent operation
  • Twist off head
  • Bellows valve construction ensures positive shut-off and leak proof operation
  • Patented construction
  • Easy to install
  • Manual open lever
  • 100% factory tested
  • 24 VAC powered with isolated end switch
  • Made in USA
  • 3 years head, 5 years body warranty
Sid Harvey Item #:B163-76: Replaces Part #:'s : B163-1 | B163-1R | ZVA3034-B163-76,

,


Item#:
B163-76
Manufacturer Item:
571-2
Manufacturer:
TACO INC.
Bell & Gossett Comfort-Trol 109054 Operator and Bonnet Assembly Conversion Kit for Zone Control Valves, 3/4", Sweat
  • MCP-12 operator and bonnet assembly conversion kit converts modumate (old style) valves to comfort trol (new style) valves
  • 24 VAC , 50/60 Hz single phase operator
  • Unique torsion spring for smooth opening and closing
  • Reliable leaf-type stack switch
  • solderless electrical connection
Sid Harvey Item #:B162-3: Replaces Part #:'s : 3437,
,

Item#:
B162-3
Manufacturer Item:
109054
Manufacturer:
BELL & GOSSETT ITT
Taco 555-050RP Replacement Power Head for 570 Gold Series Motor Zone Valves
  • 3-wire terminal block wiring
Sid Harvey Item #:B163-80: Replaces Part #:'s : 21461,
,


Taco B163-80

Item#:
B163-80
Manufacturer Item:
555-050RP
Manufacturer:
TACO INC.
White Rodgers Cooling Controls F84-0434 Valve Assembly for 1" 1311 and 1361 Series Hydronic Zone Control Valves
Sid Harvey Item #:B163-115: Replaces Part #:'s : 3C721,



Item#:
B163-115
Manufacturer Item:
F84-0434
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls B163-116 Valve Assembly For 1-1/4" 1311 & 1361 Hydronic Zone Valves,


White Rodgers B163-116

Item#:
B163-116
Manufacturer Item:
F84-0435
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Honeywell V8043F1028/U Brass 2-Way 2-Position Normally Closed Low VAC age Straight-Through Motorized Zone Valve, 1/2", Sweat
  • 2-way on-off low VAC age valves consist of an actuator and valve assembly for controlling the flow of hot water
  • Manual opener for valve operation on power failure, valve returns to automatic position when power is restored
  • All model may be installed without disassembling the valve
  • Compact construction for easy installation
  • Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
  • Actuator motor may be replaced without removing the valve body or draining the system
  • The valve can be mounted in any position on a vertical line
  • Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water
  • 15 sec nominal open timing
  • Screw terminal block electric connection
  • Spring return to close valve action
  • No SPST auxiliary end switch
  • 50 VA pilot duty at 24 VAC , 4.4 amp running with 26.4 amp inrush at 120 VAC end switch rating
  • Buna-N (NBR) rubber plug
  • Brass case, sector gears, stainless steel cover actuator
Sid Harvey Item #:B163-4: Replaces Part #:'s : 12793,
,

Item#:
B163-4
Manufacturer Item:
V8043F1028
Manufacturer:
HONEYWELL
White Rodgers Cooling Controls 1311-103 Stainless Steel 2-Way Normally Closed 3-Wire Hydronic Zone Control Valve, 1", Sweat
  • Quiet operation
  • Stainless steel valve stem
  • Automatic recycling manual operator shows valve position at all times
  • Built-in auxiliary contacts to control burner or circulator relay
  • Motor can be removed from valve assembly without draining system
  • 45 sec open and close time cycle
  • 3-1/2 feet of tubing friction loss equivalent
  • Includes screw terminal wiring panel and auxiliary switch
  • 2 amp at 24 VAC electric rating of auxiliary switch
  • 0.4 amp at 24 VAC thermostat circuit rating
Sid Harvey Item #:B163-107: Replaces Part #:'s : 24218,
Item#:
B163-107
Manufacturer Item:
1311-103
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
|◀ 37 - 48 of 123 ▶|
View: