Resideo L8148E1299 Aquastat Relay Vertical Oil Burner 120 VAC W/50 VA Transformer,

Item#:
L8148E1299
Manufacturer Item:
L8148E1299
Manufacturer:
HONEYWELL
Honeywell C292 Aquastat Remote Bulb 5' Capillary SPST Break On Rise 100-240 Degrees,
,

Item#:
C292
Manufacturer Item:
L4008A1015
Manufacturer:
HONEYWELL
Aquastat controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. Honeywell's L4006 are used in applications that utilize the existing wells.
  • Totally enclosed micro switch snap-acting switch
  • Visible control point scale and external adjustments screw permit easy setting
  • Available horizontal or vertical mounting of the remote element into boiler, tank or other container
  • Remote temperature sensing element detects and responds rapidly to temperature changes
  • Case mounts to a vertical surface
  • Includes 66" length capillary tubing, stop factory set at 240 F
Sid Harvey Item #:C293-4: Replaces Part #:'s : L39-946,
,

Item#:
C293-4
Manufacturer Item:
L6008A1192
Manufacturer:
HONEYWELL
Honeywell L8124L1011 High Limit Triple Aquastat Relay, 24/120 VAC at 60 Hz, SPST
  • Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Electrical burner rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.7 amp at 240 VAC locked rotor
  • Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
Sid Harvey Item #:C317-11: Replaces Part #:'s : AQU8124L1011-C317-11 | C317-11R |,
,

Item#:
C317-11
Manufacturer Item:
L8124L1011
Manufacturer:
HONEYWELL
Honeywell L8124A1015 Triple Aquastat Relay, 120 VAC
  • Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Electrical burner rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
  • Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
  • Includes 3" insertion well and ground screw
Sid Harvey Item #:C317-2B: Replaces Part #:'s : AQU8124A1007-C317-2B | C317-2R | C317R,
,

Item#:
C317-2B
Manufacturer Item:
L8124A1015
Manufacturer:
HONEYWELL
Honeywell L8124G1020 High Limit Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
  • Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Electrical burner rating: full load - 7.4 amp at 120 VAC line voltage, 3.7 amp at 240 VAC; locked rotor - 44.4 amp at 120 VAC line voltage, 22.7 amp at 240 VAC
  • Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor Honeywell L8124G1020 High Limit Triple Aquastat Relay, 120 VAC at 60 Hz, SPSTSid Harvey Item #:C317-8: Replaces Part #:'s : C318-8R,
    ,

Item#:
C317-8
Manufacturer Item:
L8124G1020
Manufacturer:
HONEYWELL
Honeywell L8124E1016 Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
  • Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water service
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Electrical burner rating: 1.25 amp at 24 VAC; 30 VA (total load) terminals B1-B2 and TV-Z
  • Electrical circulator rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC
Sid Harvey Item #:C317-7: Replaces Part #:'s : C317-7R,
,


Item#:
C317-7
Manufacturer Item:
L8124E1016
Manufacturer:
HONEYWELL
Amtrol Parts B135-69A Automatic Fill Valve FL-109 Fill-Trol Expansion Tanks,
,

Item#:
B135-69A
Manufacturer Item:
109-15
Manufacturer:
AMTROL INC
VxT-24 Automatic Low Water Cut-Off Water Feeder 15 psi Steam 150 psi Water 1/2" Sweat 24 VAC
  • No more trips to the basement to add water to the boiler
  • Works with all probe and float type low water cut-offs
  • Brightly illuminated feed counter displays the amount of water added to the boiler
  • Built-in memory prevents power interruptions from clearing the counter
  • Helps prevent flooded boilers, allows time for condensate to return to the boiler before starting a feed cycle
  • Six settings provide two ways to feed
  • 1 - 5 Gallon settings now feed above the probe to restore the boiler's normal operating level or select LWCO setting to end the feed cycle
  • Allows for additional make-up water at the touch of a button, manual feed amounts are recorded and added to the totalGallons displayed by the feed counter
  • If one feed cycle is not sufficient to restore boiler operation, the VxT will delay and feed one additional cycle
  • Digital feed counter
  • 30 sec to 10 min programmable feed delay settings
  • LWCO and 1 - 5 Gallon programmable feed amount settings
  • Manual feed button
  • Underfeed protection
  • Lock-out flood protection
  • 1 gpm flow rate
  • 10 VA power consumption
Sid Harvey Item #:B112-4: Replaces Part #:'s : L42-938,
,



Hydrolevel B112-4

Item#:
B112-4
Manufacturer Item:
VXT-24
Manufacturer:
HYDROLEVEL COMPANY
Gasket Domestic
Sid Harvey Item #:CO-11: Replaces Part #:'s : 13622,
,

Item#:
CO-11
Manufacturer Item:
302500
Manufacturer:
XYLEM INC.
Mcdonnell & Miller 310447 Blow-Down Ball Valve, 3/4", NPT
  • Full ported ball action valve
  • PTFE seats provide bind free, leak tight ball movement
  • Easy open handle keeps hands away from hot water and steam
  • Gasket and mounting screws included
  • For hot water and steam boilers
Sid Harvey Item #:B122-2: Replaces Part #:'s : 13552,
,

Item#:
B122-2
Manufacturer Item:
310447
Manufacturer:
XYLEM INC.
Tekmar TEKMAR256 Boiler Control 1 Stage Reset,
,

Item#:
TEKMAR256
Manufacturer Item:
TEKMAR-256
Manufacturer:
TEKMAR
|◀ 49 - 60 of 330 ▶|