|◀ 37 - 48 of 338 ▶|
View:
Sid Harvey B163-11 Replacement Zone Valve Motor

Sid Harvey B163-11

Item#:
B163-11
Manufacturer Item:
B163-11
Manufacturer:
MITCO MFG.
Honeywell V8043F1036/U Brass 2-Way/2-Position Normally Closed Low Voltage Straight-Through Zone Valve, 3/4", Sweat
    2-way on-off low Voltage valves consist of an actuator and valve assembly for controlling the flow of hot water
  • Manual opener for valve operation on power failure, valve returns to automatic position when power is restored
  • All model may be installed without disassembling the valve
  • Compact construction for easy installation
  • Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
  • Actuator motor may be replaced without removing the valve body or draining the system
  • Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water
  • 15 sec nominal open timing
  • Screw terminal block electric connection
  • Spring return to close valve action
  • No SPST auxiliary end switch
  • 50 VA pilot duty at 24 VAC , 4.4 amp running with 26.4 amp inrush at 120 VAC end switch rating
  • Buna-N (NBR) rubber plug
  • Manual opener

    HONEYWELL B163-5

Item#:
B163-5
Manufacturer Item:
V8043F1036
Manufacturer:
HONEYWELL
White Rodgers Cooling Controls F19-0097 3-Wire Motor Assembly for 3-Wire Zone Valves 1311-102, -103, -104

White Rodgers B163-112

Item#:
B163-112
Manufacturer Item:
F19-0097
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Honeywell V8043F1051/U Brass 2-Way/2-Position Normally Closed Low Voltage Straight-Through Zone Valve, 1", Sweat
    2-way on-off low Voltage valves consist of an actuator and valve assembly for controlling the flow of hot water
  • Manual opener for valve operation on power failure, valve returns to automatic position when power is restored
  • All model may be installed without disassembling the valve
  • Compact construction for easy installation
  • Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
  • Actuator motor may be replaced without removing the valve body or draining the system
  • Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water
  • 15 sec nominal open timing
  • Screw terminal block electric connection
  • Spring return to close valve action
  • No SPST auxiliary end switch
  • 50 VA pilot duty at 24 VAC , 4.4 amp running with 26.4 amp inrush at 120 VAC end switch rating
  • Buna-N (NBR) rubber plug

    Honeywell B163-6

Item#:
B163-6
Manufacturer Item:
V8043F1051
Manufacturer:
HONEYWELL
White Rodgers Cooling Controls B163-108 2-Way 3-Wire Normally Closed Hydronic Zone Control Valve 1-1/4" Sweat,

White Rodgers B163-108

Item#:
B163-108
Manufacturer Item:
1311-104
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Taco heat motor zone valves provide a time proven method for system zoning and control. The exclusive heat motor design operates silently, while the twist off head allows for serviceability without disturbing system connections.
    Heat motor zone valves provide a convenient way to create individual zones or equipment isolation in a hydronic heating system
  • Using multiple heat motor zone valves and a single pump, you can start, stop or divert flow through the system to provide individual room or area comfort control and energy savings
  • Rugged dependability
  • Silent operation
  • Twist off head
  • Bellows valve construction ensures positive shut-off and leak proof operation
  • Patented construction
  • Easy to install
  • Manual open lever
  • 100% factory tested
  • 24 VAC powered with isolated end switch
  • Made in USA
  • 3 years head, 5 years body warranty

    Taco B163-76

Item#:
B163-76
Manufacturer Item:
571-2
Manufacturer:
TACO INC.
Bell & Gossett Comfort-Trol 109054 Operator and Bonnet Assembly Conversion Kit for Zone Control Valves, 3/4", Sweat
    MCP-12 operator and bonnet assembly conversion kit converts modumate (old style) valves to comfort trol (new style) valves
  • 24 VAC , 50/60 Hz single phase operator
  • Unique torsion spring for smooth opening and closing
  • Reliable leaf-type stack switch
  • solderless electrical connection

    Bell & Gossett B162-3

Item#:
B162-3
Manufacturer Item:
109054
Manufacturer:
BELL & GOSSETT ITT
Taco 555-050RP Replacement Power Head for 570 Gold Series Motor Zone Valves
    3-wire terminal block wiring

    Taco B163-80

Item#:
B163-80
Manufacturer Item:
555-050RP
Manufacturer:
TACO INC.
White Rodgers Cooling Controls F84-0434 Valve Assembly for 1" 1311 and 1361 Series Hydronic Zone Control Valves

White Rodgers B163-115

Item#:
B163-115
Manufacturer Item:
F84-0434
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls B163-116 Valve Assembly For 1-1/4" 1311 & 1361 Hydronic Zone Valves

White Rodgers B163-116

Item#:
B163-116
Manufacturer Item:
F84-0435
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Honeywell V8043F1028/U Brass 2-Way 2-Position Normally Closed Low Voltage Straight-Through Motorized Zone Valve, 1/2", Sweat
    2-way on-off low Voltage valves consist of an actuator and valve assembly for controlling the flow of hot water
  • Manual opener for valve operation on power failure, valve returns to automatic position when power is restored
  • All model may be installed without disassembling the valve
  • Compact construction for easy installation
  • Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
  • Actuator motor may be replaced without removing the valve body or draining the system
  • The valve can be mounted in any position on a vertical line
  • Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water
  • 15 sec nominal open timing
  • Screw terminal block electric connection
  • Spring return to close valve action
  • No SPST auxiliary end switch
  • 50 VA pilot duty at 24 VAC , 4.4 amp running with 26.4 amp inrush at 120 VAC end switch rating
  • Buna-N (NBR) rubber plug
  • Brass case, sector gears, stainless steel cover actuator

    Honeywell B163-4

Item#:
B163-4
Manufacturer Item:
V8043F1028
Manufacturer:
HONEYWELL
White Rodgers Cooling Controls 1311-103 Stainless Steel 2-Way Normally Closed 3-Wire Hydronic Zone Control Valve, 1", Sweat
    Quiet operation
  • Stainless steel valve stem
  • Automatic recycling manual operator shows valve position at all times
  • Built-in auxiliary contacts to control burner or circulator relay
  • Motor can be removed from valve assembly without draining system
  • 45 sec open and close time cycle
  • 3-1/2 feet of tubing friction loss equivalent
  • Includes screw terminal wiring panel and auxiliary switch
  • 2 amp at 24 VAC electric rating of auxiliary switch
  • 0.4 amp at 24 VAC thermostat circuit rating
Sid Harvey Item #:B163-107: Replaces Part #:'s : 24218,

White Rodgers B163-107

Item#:
B163-107
Manufacturer Item:
1311-103
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
|◀ 37 - 48 of 338 ▶|
View: