Honeywell C292 Aquastat Remote Bulb 5' Capillary SPST Break On Rise 100-240 Degrees,
Honeywell L4081B1096/U High Limit Circulator Aquastat Control, 110 - 220 deg F Low, 130 - 240 deg F High
- An immersion type liquid-filled sensing element actuates (2) snap switches
- (1) switch operates as a high limit control
- The other switch operates as a low limit and/or circulator control, depending on the model
- Controller may be mounted in any positioning and needs no leveling
- Separate, easy-to-read, calibrated dial and setpoint adjustments for each switch
- Differential adjustment on low limit or circulator switch on select models
- All adjustments accessible inside front cover
- Push-in terminals for quick connecting
- 1-sensing element for easy installation
- (2) SPST snap switches act independently at respective temperature settings
- 3" insulation depth
- 360 VA transformer load ignition electrical ratings
- High limit, low limit and/or circulator controllers used to regulate boiler water temperature in gas- or oil-fired hydronic heating systems
Item#:
C322-4A
Manufacturer Item:
L4081B1096
Manufacturer:
HONEYWELL
Aquastat controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. Honeywell's L4006 are used in applications that utilize the existing wells.
- Totally enclosed micro switch snap-acting switches operate on temperature rise to setpoint
- Visible control point scale and external adjustments screw permit easy setting
- Horizontal or vertical insertion of the sensing element
- Remote bulb model may be used to sense air temperature in ducts and in outside air sensing applications
- Direct or well immersion of the sensing element
- Includes heat-conductive compound, well adapter Honeywell L4006E1067 High Limit Manual Reset Aquastat, 130 - 270 deg F, 10 - 25 deg F Differential
Honeywell L8148J1009/U Aquastat Relay, 120 VAC at 60 Hz, SPST, 120 - 240 deg F High Limit, 8 deg F Fixed Differential
- Immersion-type controllers that combine high limit protection with switching relay control of burner and circulator motors
- High limit opens burner circuit only
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
- 1-1/2 - 3" depth less well insulation
- Electrical burner rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC; millivolt: 0.25 amp at 1/4 - 12 VDC
- Electrical circulator rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC Honeywell L8148J1009/U Aquastat Relay, 120 VAC at 60 Hz, SPST, 120 - 240 deg F High Limit, 8 deg F Fixed Differential
The L8148 Aquastat Relays are immersion type hydronic controllers that combine high limit protection with switching relay control of burner and circulator motors.
Item#:
C312-8
Manufacturer Item:
L8148A1017
Manufacturer:
HONEYWELL
Aquastat controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. Honeywell's L4006 are used in applications that utilize the existing wells.
- Totally enclosed micro switch snap acting switches operate on temperature rise to setpoint
- Visible control point scale and external adjustments screw permit easy setting
- Horizontal insertion of the sensing element
- Direct/well immersion of the sensing element
- Remote bulb model may be used to sense air temperature in ducts and in outside air sensing applications
- Contacts make on temperature rise
- Screw terminals wiring
Honeywell L8124C1003 Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
- Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water service
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
- Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Electrical burner rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC line voltage; at locked rotor: 44.4 amp at 120 VAC, 22.7 amp at 240 VAC line voltage
- Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
- 1-1/2" depth insulation
Item#:
C317-5
Manufacturer Item:
L8124C1003
Manufacturer:
HONEYWELL
Honeywell L8124G1020 High Limit Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
- Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
- Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Electrical burner rating: full load - 7.4 amp at 120 VAC line voltage, 3.7 amp at 240 VAC; locked rotor - 44.4 amp at 120 VAC line voltage, 22.7 amp at 240 VAC
- Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor Honeywell L8124G1020 High Limit Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
Item#:
C317-8
Manufacturer Item:
L8124G1020
Manufacturer:
HONEYWELL
Honeywell L8124E1016 Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
- Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water service
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
- Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Electrical burner rating: 1.25 amp at 24 VAC; 30 VA (total load) terminals B1-B2 and TV-Z
- Electrical circulator rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC
Item#:
C317-7
Manufacturer Item:
L8124E1016
Manufacturer:
HONEYWELL
Honeywell L8124A1015 Triple Aquastat Relay, 120 VAC
- Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
- Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Electrical burner rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
- Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
- Includes 3" insertion well and ground screw
Item#:
C317-2B
Manufacturer Item:
L8124A1015
Manufacturer:
HONEYWELL
Honeywell L8124L1011 High Limit Triple Aquastat Relay, 24/120 VAC at 60 Hz, SPST
- Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
- Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Electrical burner rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.7 amp at 240 VAC locked rotor
- Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
Item#:
C317-11
Manufacturer Item:
L8124L1011
Manufacturer:
HONEYWELL
Aquastat controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. Honeywell's L4006 are used in applications that utilize the existing wells.
- Totally enclosed micro switch snap-acting switch
- Visible control point scale and external adjustments screw permit easy setting
- Available horizontal or vertical mounting of the remote element into boiler, tank or other container
- Remote temperature sensing element detects and responds rapidly to temperature changes
- Case mounts to a vertical surface
- Includes 66" length capillary tubing, stop factory set at 240 F