Honeywell C293-3 Aquastat Immersion High or Low Limit SPDT 110-240 Degrees,
Honeywell C293-3
Honeywell C293-3
Honeywell C293-3
Honeywell C320-15 Dual Aquastat High Limit/Low Limit or Pump
Nordic Technology FAST-STAT5000
Aquastat controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. Honeywell's L4006 are used in applications that utilize the existing wells.
- Totally enclosed micro switch snap acting switches operate on temperature rise to setpoint
- Visible control point scale and external adjustments screw permit easy setting
- Horizontal or vertical insertion of the sensing element
- Direct/well immersion of the sensing element
- Remote bulb model may be used to sense air temperature in ducts and in outside air sensing applications
- Contacts break on temperature rise
- Screw terminals wiring
Honeywell C290-6A
Honeywell L8124G1020 High Limit Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
- Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
- Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Electrical burner rating: full load - 7.4 amp at 120 VAC line voltage, 3.7 amp at 240 VAC; locked rotor - 44.4 amp at 120 VAC line voltage, 22.7 amp at 240 VAC
- Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor Honeywell L8124G1020 High Limit Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
Honeywell C317-8
Item#:
C317-8
Manufacturer Item:
L8124G1020
Manufacturer:
HONEYWELL
Honeywell L8124A1015 Triple Aquastat Relay, 120 VAC
- Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
- Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Electrical burner rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
- Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
- Includes 3" insertion well and ground screw
Honeywell C317-2B
Item#:
C317-2B
Manufacturer Item:
L8124A1015
Manufacturer:
HONEYWELL
Honeywell L8148J1009/U Aquastat Relay, 120 VAC at 60 Hz, SPST, 120 - 240 deg F High Limit, 8 deg F Fixed Differential
- Immersion-type controllers that combine high limit protection with switching relay control of burner and circulator motors
- High limit opens burner circuit only
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
- 1-1/2 - 3" depth less well insulation
- Electrical burner rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC; millivolt: 0.25 amp at 1/4 - 12 VDC
- Electrical circulator rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC Honeywell L8148J1009/U Aquastat Relay, 120 VAC at 60 Hz, SPST, 120 - 240 deg F High Limit, 8 deg F Fixed Differential
Honeywell C312-9
Gorton Heating Corp C18A Steel #C Angle Air Vent Valve, 1/8", MNPT
- Non adjustment
Gorton Heating C18A
Honeywell L8124C1003 Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
- Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water service
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
- Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Electrical burner rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC line voltage; at locked rotor: 44.4 amp at 120 VAC, 22.7 amp at 240 VAC line voltage
- Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
- 1-1/2" depth insulation
Honeywell C317-5
Item#:
C317-5
Manufacturer Item:
L8124C1003
Manufacturer:
HONEYWELL
Honeywell C292 Aquastat Remote Bulb 5' Capillary SPST Break On Rise 100-240 Degrees,
Honeywell C292
Aquastat controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. Honeywell's L4006 are used in applications that utilize the existing wells.
- Totally enclosed micro switch snap acting switches operate on temperature rise to setpoint
- Visible control point scale and external adjustments screw permit easy setting
- Horizontal insertion of the sensing element
- Direct/well immersion of the sensing element
- Remote bulb model may be used to sense air temperature in ducts and in outside air sensing applications
- Contacts make on temperature rise
- Screw terminals wiring
Honeywell C290-1A
Honeywell L8124L1011 High Limit Triple Aquastat Relay, 24/120 VAC at 60 Hz, SPST
- Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
- Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Electrical burner rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.7 amp at 240 VAC locked rotor
- Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
Honeywell C317-11
Item#:
C317-11
Manufacturer Item:
L8124L1011
Manufacturer:
HONEYWELL
The L8148 Aquastat Relays are immersion type hydronic controllers that combine high limit protection with switching relay control of burner and circulator motors.
Honeywell C312-8
Item#:
C312-8
Manufacturer Item:
L8148A1017
Manufacturer:
HONEYWELL