Honeywell Protectorelay R8184M1051 Oil Burner Control for Boilers, 120 - 240 VAC
- Operates the oil burner and oil valve (if desired) in response to a call for heat from a low voltage control circuit
- Intermittent ignition is on while the burner is on
- Solid state flame sensing circuit
- External button to manually reset safety switch after lockout
- Enclosed safety switch must be manually reset after safety shutdown
- R8184M includes 40 VA transformer and Y and G terminals for connection of cooling equipment
- Mounts on standard 4 x 4" junction box
- C554A cadmium sulfide flame detector and 24 VAC thermostat required
honeywell r75-58
Carlin Parts 6020002S015120 CAD Cell Oil Primary Control, 15 sec Trial
- Interrupted duty ignition
- Recycle on flame failure
- Serviceman reset protection (latch-up after 3-consecutive lockouts)
- Diagnostic LED
- Valve delay on/motor delay off (pre/post-purge)
- 15 sec trial for ignition (TFI) other timings available
- 1.3 sec flame failure response time (FFRT)
- Alarm contacts
- Thermostat/aquastat compatible
- SMC (safety monitoring circuit) technology
carlin parts r77-44
Item#:
R77-44
Manufacturer Item:
6020002S015120
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin Parts 42230-02S CAD Cell Oil Primary Control for Thermostat/Aquastat Compatible, 120 VAC, 500 watt
- Interrupted duty ignition for high efficiency
- SMC technology for safety monitoring
- Diagnostic LED indicators
- Secondary burner control has a input voltage rating of 120 VAC, input frequency rating of 60 Hz and input power rating of 10 VA from limit circuit
- 15 sec trial for Ignition 40200 (1.3 sec flame failure response time (FFRT))
- 30 sec trial for Ignition 42230 (1.3 sec flame failure response time (FFRT)
- Recycle on flame failure
- It has a temperature rating of 32 - 140 deg F and resistive rating of 1500 ohm
- Valve delay on/motor delay off for economic as well as efficient performance
- It has a motor load of 10 FLA/60 LRA and ignitor load of 120 VAC at 60 Hz
- 500 VA motor load
carlin parts r75-45
Item#:
R75-45
Manufacturer Item:
4223002S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin Parts 48245S Intermittent Duty Oil Burner Primary Control, 120 VAC
- 45 sec trial for ignition
- Red LED lockout indicator
- Thermostat/aquastat compatible SMC (safety monitoring circuit) technology
- 5 amp full load, 60 amp locked rotor motor load
- 120 VAC, 60 Hz, 500 VA igniter load
carlin parts r75-47
Item#:
R75-47
Manufacturer Item:
48245S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Oilco OC-10 CAD Cell Eye for Oil Primary Controls
Sid Harvey R80-100
Item#:
R80-100
Manufacturer Item:
OC-10
Manufacturer:
OILCO COMPANY
White Rodgers Cooling Controls 956-1 Standard Cad Cell Flame Detector with Straight Bracket, 48-1/2" L Lead
- Utilizes light intensity to sense the presence of a flame in oil burning heating equipment
- Includes cadmium sulfide sensor cell, mounting bracket assembly
White Rodgers R83
Item#:
R83
Manufacturer Item:
956-1
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Honeywell C554A1794 Cadmium-Sulfide Flame Detector for Oil Fired Burner
- With 60 Inch lead
- Photoconductive flame sensing device for sequencing oil burner systems
- On flame failure, the light sensitive cadmium sulfide cell, in conjunction with flame sensing circuitry, causes the protectorelay control to shutdown the main oil burner
- Glass-to-metal hermetic seal in plug-in cell prevents deterioration by humidity, soot or oil fumes
- Replaceable 130367 cad cell
- Includes type E mounting bracket and fuel line adaptor
- Used with R4166, R4184, R8182, R8184, R8185, R8404, R8991, R7997, R7184, R7284
- Minimum sensitivity at 2 feet candles
Honeywell R82
Item#:
R82
Manufacturer Item:
C554A1794
Manufacturer:
MITCO MFG.
Sid Harvey 70064 Pre-Assembled Flame Detector Kit
- Includes E-style mounting bracket, Beckett cad cell eye, 30 Inch leads
Sid Harvey R82-4
Item#:
R82-4
Manufacturer Item:
70064
Manufacturer:
MITCO MFG.
Sid Harvey R82-2 Cadium Sulfide Flame Detector Kit, 60"Lead f/ A, E, J, & P Type
- For sequencing oil burner systems use with protectorelay oil primary controls such as R4166, R4184, R8182, R8184, and R8404.
- 2-piece model cell plug ins.
- Includes: 4 different style mounting brackets oil line bracket, cad cell eye, 60" leads
honeywell r82-2
Item#:
R82-2
Manufacturer Item:
C554A1463
Manufacturer:
MITCO MFG.
Honeywell 120320 Cad Cell Eye for Use with Oil Primary Control in Burner
honeywell r82-1
Item#:
R82-1
Manufacturer Item:
120320/U
Manufacturer:
HONEYWELL
Riello 20132573 Cad Cell Eye for Use with Oil Primary Control
Riello Parts 20132573
Item#:
20132573
Manufacturer Item:
20132573
Manufacturer:
RIELLO CORP OF AMERICA
Riello 20010004 Primary Control for R40 F3-F5-F10-F15-F20, BF3, BF5 Oil Burners with Manual and 530SE/C24V Hydraulic Air Shutter
Riello Parts 20010004
Item#:
20010004
Manufacturer Item:
20010004
Manufacturer:
RIELLO CORP OF AMERICA