Brand Name
Voltage
Lockout Time
Ignition Type
|◀ 13 - 24 of 39 ▶|
View:
Honeywell Protectorelay R8184M1051 Oil Burner Control for Boilers, 120 - 240 VAC
    Operates the oil burner and oil valve (if desired) in response to a call for heat from a low voltage control circuit
  • Intermittent ignition is on while the burner is on
  • Solid state flame sensing circuit
  • External button to manually reset safety switch after lockout
  • Enclosed safety switch must be manually reset after safety shutdown
  • R8184M includes 40 VA transformer and Y and G terminals for connection of cooling equipment
  • Mounts on standard 4 x 4" junction box
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required

    honeywell r75-58

Item#:
R75-58
Manufacturer Item:
R8184M1051
Manufacturer:
HONEYWELL
Carlin Parts 6020002S015120 CAD Cell Oil Primary Control, 15 sec Trial
    Interrupted duty ignition
  • Recycle on flame failure
  • Serviceman reset protection (latch-up after 3-consecutive lockouts)
  • Diagnostic LED
  • Valve delay on/motor delay off (pre/post-purge)
  • 15 sec trial for ignition (TFI) other timings available
  • 1.3 sec flame failure response time (FFRT)
  • Alarm contacts
  • Thermostat/aquastat compatible
  • SMC (safety monitoring circuit) technology

    carlin parts r77-44

Item#:
R77-44
Manufacturer Item:
6020002S015120
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin Parts 42230-02S CAD Cell Oil Primary Control for Thermostat/Aquastat Compatible, 120 VAC, 500 watt
    Interrupted duty ignition for high efficiency
  • SMC technology for safety monitoring
  • Diagnostic LED indicators
  • Secondary burner control has a input voltage rating of 120 VAC, input frequency rating of 60 Hz and input power rating of 10 VA from limit circuit
  • 15 sec trial for Ignition 40200 (1.3 sec flame failure response time (FFRT))
  • 30 sec trial for Ignition 42230 (1.3 sec flame failure response time (FFRT)
  • Recycle on flame failure
  • It has a temperature rating of 32 - 140 deg F and resistive rating of 1500 ohm
  • Valve delay on/motor delay off for economic as well as efficient performance
  • It has a motor load of 10 FLA/60 LRA and ignitor load of 120 VAC at 60 Hz
  • 500 VA motor load

    carlin parts r75-45

Item#:
R75-45
Manufacturer Item:
4223002S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin Parts 48245S Intermittent Duty Oil Burner Primary Control, 120 VAC
    45 sec trial for ignition
  • Red LED lockout indicator
  • Thermostat/aquastat compatible SMC (safety monitoring circuit) technology
  • 5 amp full load, 60 amp locked rotor motor load
  • 120 VAC, 60 Hz, 500 VA igniter load

    carlin parts r75-47

Item#:
R75-47
Manufacturer Item:
48245S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Oilco OC-10 CAD Cell Eye for Oil Primary Controls

Sid Harvey R80-100

Item#:
R80-100
Manufacturer Item:
OC-10
Manufacturer:
OILCO COMPANY
White Rodgers Cooling Controls 956-1 Standard Cad Cell Flame Detector with Straight Bracket, 48-1/2" L Lead
    Utilizes light intensity to sense the presence of a flame in oil burning heating equipment
  • Includes cadmium sulfide sensor cell, mounting bracket assembly

    White Rodgers R83

Item#:
R83
Manufacturer Item:
956-1
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Honeywell C554A1794 Cadmium-Sulfide Flame Detector for Oil Fired Burner
    With 60 Inch lead
  • Photoconductive flame sensing device for sequencing oil burner systems
  • On flame failure, the light sensitive cadmium sulfide cell, in conjunction with flame sensing circuitry, causes the protectorelay control to shutdown the main oil burner
  • Glass-to-metal hermetic seal in plug-in cell prevents deterioration by humidity, soot or oil fumes
  • Replaceable 130367 cad cell
  • Includes type E mounting bracket and fuel line adaptor
  • Used with R4166, R4184, R8182, R8184, R8185, R8404, R8991, R7997, R7184, R7284
  • Minimum sensitivity at 2 feet candles

    Honeywell R82

Item#:
R82
Manufacturer Item:
C554A1794
Manufacturer:
MITCO MFG.
Sid Harvey 70064 Pre-Assembled Flame Detector Kit
    Includes E-style mounting bracket, Beckett cad cell eye, 30 Inch leads

    Sid Harvey R82-4

Item#:
R82-4
Manufacturer Item:
70064
Manufacturer:
MITCO MFG.
Sid Harvey R82-2 Cadium Sulfide Flame Detector Kit, 60"Lead f/ A, E, J, & P Type
    For sequencing oil burner systems use with protectorelay oil primary controls such as R4166, R4184, R8182, R8184, and R8404.
  • 2-piece model cell plug ins.
  • Includes: 4 different style mounting brackets oil line bracket, cad cell eye, 60" leads

    honeywell r82-2

Item#:
R82-2
Manufacturer Item:
C554A1463
Manufacturer:
MITCO MFG.
Honeywell 120320 Cad Cell Eye for Use with Oil Primary Control in Burner

honeywell r82-1

Item#:
R82-1
Manufacturer Item:
120320/U
Manufacturer:
HONEYWELL
Riello 20132573 Cad Cell Eye for Use with Oil Primary Control

Riello Parts 20132573

Item#:
20132573
Manufacturer Item:
20132573
Manufacturer:
RIELLO CORP OF AMERICA
Riello 20010004 Primary Control for R40 F3-F5-F10-F15-F20, BF3, BF5 Oil Burners with Manual and 530SE/C24V Hydraulic Air Shutter

Riello Parts 20010004

Item#:
20010004
Manufacturer Item:
20010004
Manufacturer:
RIELLO CORP OF AMERICA
|◀ 13 - 24 of 39 ▶|