-Narrow Your Search
View:
BoxesList
Compare Selected Items
Quick View
Mitco R80-100-1 Cadcell Larger Pin

Mitco R80-100-1

Item#:
R80-100-1
Manufacturer Item:
OC-10-1
Manufacturer:
OILCO COMPANY
Quick View
ICM Controls ICM1501 Oil Burner PrimaryControl, 7.4 A at 120 VAC/3.7 amp at 240 VAC Full Load, Intermittent Ignition
    Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • LED on terminal strip indicates system lockout
  • Enclosed safety switch with external reset butTon
  • Mounts on standard 4 x 4" junction box (select models may be mounted directly on burner housing)
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
  • Replacement for popular competitive models
  • 44.4 amp at 120 VAC/22.2 amp at 240 VAC (contacts - locked rotor)
  • Direct replacement for Honeywell R8184G1161/R8184G1294/R8184G4066 Replaces Part #:'s : R8184G1161 | R8184G1294 |

    ICM Controls ICM1501

Item#:
ICM1501
Manufacturer Item:
ICM1501
Manufacturer:
ICM INTERNATIONAL
Quick View
ICM Controls ICM1502 Intermittent Oil Primary Control, 120/240 VAC, Domestic
    Intermittent ignition oil primary control with 30 sec safety timing, replacement for Honeywell R8184G Series
  • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • LED on terminal strip indicates system lockout
  • Enclosed safety switch with external reset butTon
  • Mounts on standard 4 x 4" junction box (select models may be mounted directly on burner housing)
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
  • Replacement for popular competitive models

    ICM Controls ICM1502

Item#:
ICM1502
Manufacturer Item:
ICM1502
Manufacturer:
ICM INTERNATIONAL
Quick View
ICM Controls ICM1503 Intermittent Oil Primary Control, 120/240 VAC, Domestic
    Intermittent ignition oil primary control with 45 sec safety timing, replacement for Honeywell R8184G Series
  • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • LED on terminal strip indicates system lockout
  • Enclosed safety switch with external reset butTon
  • Mounts on standard 4 x 4" junction box (select models may be mounted directly on burner housing)
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
  • Replacement for popular competitive models

    ICM Controls ICM1503

Item#:
ICM1503
Manufacturer Item:
ICM1503
Manufacturer:
ICM INTERNATIONAL
Quick View
Carlin Parts 50200-02S CAD Cell Oil Primary Control for Oil and Gas, Residential and Commercial Burners, Controls and Igniters
    Interrupted duty ignition
  • Recycle on flame failure
  • Serviceman reset protection (latch-up after 3-consecutive lockouts)
  • Diagnostic LED
  • 15 sec trial for ignition (TFI) other timings available
  • 1.3 sec flame failure response time (FFRT)
  • Alarm contacts
  • Thermostat/aquastat compatible
  • SMC (safety monitoring circuit) technology

    Carlin Parts R77-40

Item#:
R77-40
Manufacturer Item:
5020002S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Quick View
White Rodgers Cooling Controls 956-1 Standard Cad Cell Flame Detector with Straight Bracket, 48-1/2" L Lead
    Utilizes light intensity to sense the presence of a flame in oil burning heating equipment
  • Includes cadmium sulfide sensor cell, mounting bracket assembly

    White Rodgers R83

Item#:
R83
Manufacturer Item:
956-1
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Quick View
Resideo R7284B1024 Oil Burner Primary Control 15 Second Lockout Timing Interrupted Ignition

Resideo R7284B1024

Item#:
R7284B1024
Manufacturer Item:
R7284B1024
Manufacturer:
HONEYWELL
Quick View
Honeywell C554A1794 Cadmium-Sulfide Flame Detector for Oil Fired Burner
    With 60 Inch lead
  • Photoconductive flame sensing device for sequencing oil burner systems
  • On flame failure, the light sensitive cadmium sulfide cell, in conjunction with flame sensing circuitry, causes the protectorelay control to shutdown the main oil burner
  • Glass-to-metal hermetic seal in plug-in cell prevents deterioration by humidity, soot or oil fumes
  • Replaceable 130367 cad cell
  • Includes type E mounting bracket and fuel line adaptor
  • Used with R4166, R4184, R8182, R8184, R8185, R8404, R8991, R7997, R7184, R7284
  • Minimum sensitivity at 2 feet candles

    Honeywell R82

Item#:
R82
Manufacturer Item:
C554A1794
Manufacturer:
MITCO MFG.
Quick View
Sid Harvey 70064 Pre-Assembled Flame Detector Kit
    Includes E-style mounting bracket, Beckett cad cell eye, 30 Inch leads

    Sid Harvey R82-4

Item#:
R82-4
Manufacturer Item:
70064
Manufacturer:
MITCO MFG.
Quick View
Carlin Parts 40200-02S CAD Cell Oil Primary Control for Oil and Gas, Residential and Commercial Burners, Controls and Igniters
    Interrupted duty ignition
  • 15 sec trial for Ignition 40200 (1.3 sec flame failure response time (FFRT))
  • Recycle on flame failure
  • Thermostat/aquastat compatible
  • SMC (safety monitoring circuit) technology

    carlin parts r77-10

Item#:
R77-10
Manufacturer Item:
40200-02S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Quick View
Carlin Parts Combustion Technology, Inc. the industrys technological leader in oil and gas, residential and commercial burners, controls and igniters.
    Interrupted duty ignition for high efficiency
  • SMC technology for safety monitoring
  • LED indicators, alarm contacts and pump prime for economic as well as efficient performance
  • Serviceman reset protection ( latch-up after three consecutive lockouts)
  • 15 sec trial for ignition (TFI) other timings available
  • It offers recycle on flame failure and 1.3 sec flame failure response time
  • Oil primary control has a input voltage rating of 120 VAC, input frequency rating of 60 Hz and input power rating of 9 VA
  • It has a temperature rating of 32 - 140 deg F, resistive rating of 1500 ohm and safety switch timing of 15 sec
  • Primary control offers serviceman reset protection and valve delay on/motor delay off feature
  • It has a motor load of 10 FLA/60 LRA, ignitor load of 120 VAC at 60 Hz and valve load of 120 VAC at 60 Hz
  • 500 VA motor load
  • 24 VAC/VDC, 2 amp alarm contacts
  • Flame signal test jack
Sid Harvey Item #:R77-41: Replaces Part #:'s : 7G998,
carlin parts r77-41

Carlin Parts R77-41

Item#:
R77-41
Manufacturer Item:
6020002S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Quick View
Resideo R7284U1004 Oil Burner Primary Control 15/30/45 Second Lockout Timing

Resideo R7284U1004

Item#:
R7284U1004
Manufacturer Item:
R7284U1004
Manufacturer:
HONEYWELL
View:
BoxesList
Compare Selected Items