Brand Name
Voltage
Lockout Time
Ignition Type
View:
Mitco R80-100-1 Cadcell Larger Pin

Mitco R80-100-1

Item#:
R80-100-1
Manufacturer Item:
OC-10-1
Manufacturer:
OILCO COMPANY
ICM Controls ICM1501 Oil Burner PrimaryControl, 7.4 A at 120 VAC/3.7 amp at 240 VAC Full Load, Intermittent Ignition
    Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • LED on terminal strip indicates system lockout
  • Enclosed safety switch with external reset butTon
  • Mounts on standard 4 x 4" junction box (select models may be mounted directly on burner housing)
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
  • Replacement for popular competitive models
  • 44.4 amp at 120 VAC/22.2 amp at 240 VAC (contacts - locked rotor)
  • Direct replacement for Honeywell R8184G1161/R8184G1294/R8184G4066 Replaces Part #:'s : R8184G1161 | R8184G1294 |

    ICM Controls ICM1501

Item#:
ICM1501
Manufacturer Item:
ICM1501
Manufacturer:
ICM INTERNATIONAL
ICM Controls ICM1502 Intermittent Oil Primary Control, 120/240 VAC, Domestic
    Intermittent ignition oil primary control with 30 sec safety timing, replacement for Honeywell R8184G Series
  • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • LED on terminal strip indicates system lockout
  • Enclosed safety switch with external reset butTon
  • Mounts on standard 4 x 4" junction box (select models may be mounted directly on burner housing)
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
  • Replacement for popular competitive models

    ICM Controls ICM1502

Item#:
ICM1502
Manufacturer Item:
ICM1502
Manufacturer:
ICM INTERNATIONAL
ICM Controls ICM1503 Intermittent Oil Primary Control, 120/240 VAC, Domestic
    Intermittent ignition oil primary control with 45 sec safety timing, replacement for Honeywell R8184G Series
  • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • LED on terminal strip indicates system lockout
  • Enclosed safety switch with external reset butTon
  • Mounts on standard 4 x 4" junction box (select models may be mounted directly on burner housing)
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
  • Replacement for popular competitive models

    icm controls icm1503

Item#:
ICM1503
Manufacturer Item:
ICM1503
Manufacturer:
ICM INTERNATIONAL
Carlin Parts 50200-02S CAD Cell Oil Primary Control for Oil and Gas, Residential and Commercial Burners, Controls and Igniters
    Interrupted duty ignition
  • Recycle on flame failure
  • Serviceman reset protection (latch-up after 3-consecutive lockouts)
  • Diagnostic LED
  • 15 sec trial for ignition (TFI) other timings available
  • 1.3 sec flame failure response time (FFRT)
  • Alarm contacts
  • Thermostat/aquastat compatible
  • SMC (safety monitoring circuit) technology

    carlin parts r77-40

Item#:
R77-40
Manufacturer Item:
5020002S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Resideo R7284B1024 Oil Burner Primary Control 15 Second Lockout Timing Interrupted Ignition

Resideo R7284B1024

Item#:
R7284B1024
Manufacturer Item:
R7284B1024
Manufacturer:
HONEYWELL
Carlin Parts 40200-02S CAD Cell Oil Primary Control for Oil and Gas, Residential and Commercial Burners, Controls and Igniters
    Interrupted duty ignition
  • 15 sec trial for Ignition 40200 (1.3 sec flame failure response time (FFRT))
  • Recycle on flame failure
  • Thermostat/aquastat compatible
  • SMC (safety monitoring circuit) technology

    carlin parts r77-10

Item#:
R77-10
Manufacturer Item:
40200-02S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin Parts Combustion Technology, Inc. the industrys technological leader in oil and gas, residential and commercial burners, controls and igniters.
    Interrupted duty ignition for high efficiency
  • SMC technology for safety monitoring
  • LED indicators, alarm contacts and pump prime for economic as well as efficient performance
  • Serviceman reset protection ( latch-up after three consecutive lockouts)
  • 15 sec trial for ignition (TFI) other timings available
  • It offers recycle on flame failure and 1.3 sec flame failure response time
  • Oil primary control has a input voltage rating of 120 VAC, input frequency rating of 60 Hz and input power rating of 9 VA
  • It has a temperature rating of 32 - 140 deg F, resistive rating of 1500 ohm and safety switch timing of 15 sec
  • Primary control offers serviceman reset protection and valve delay on/motor delay off feature
  • It has a motor load of 10 FLA/60 LRA, ignitor load of 120 VAC at 60 Hz and valve load of 120 VAC at 60 Hz
  • 500 VA motor load
  • 24 VAC/VDC, 2 amp alarm contacts
  • Flame signal test jack
Sid Harvey Item #:R77-41: Replaces Part #:'s : 7G998,
carlin parts r77-41

carlin parts r77-41

Item#:
R77-41
Manufacturer Item:
6020002S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Resideo R7284U1004 Oil Burner Primary Control 15/30/45 Second Lockout Timing

Resideo R7284U1004

Item#:
R7284U1004
Manufacturer Item:
R7284U1004
Manufacturer:
HONEYWELL
Honeywell R8184G4009 Non-Recycle Oil Burner Control with Safety Timing, 120/220/240 volt
    Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • LED on terminal strip indicates system lockout
  • Remote lockout indication
  • Enclosed safety switch with external reset button
  • Manual trip lever opens safety switch for system maintenance
  • Mounts on standard 4 x 4" junction box
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
  • With 15 sec safety timing, alarm outputs and manual safety switch
Sid Harvey Item #:R75-40: Replaces Part #:'s : R75-39R | R75-40R | ICM150

honeywell r75-40

Item#:
R75-40
Manufacturer Item:
R8184G4009
Manufacturer:
HONEYWELL
Honeywell Protectorelay R8184G4066/U Non-Recycle Oil Burner Control with Safety Timing, 4-1/8" W x 4-3/8" H x 2-1/2" Depth
    Provides automatic, non-recycling control of an intermittent ignition oil burner system
  • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • LED on terminal strip indicates system lockout
  • Remote lockout indication
  • Enclosed safety switch with external reset button
  • Manual trip lever opens safety switch for system maintenance
  • Mounts on standard 4 x 4" junction box (select models may be mounted directly on burner housing)
  • C554A cadmium sulfide flame detector and 24 volts thermostat required
  • 15 second safety timing, alarm outputs, and manual safety switch
  • Intermittent ignition timing

    honeywell r75-37

Item#:
R75-37
Manufacturer Item:
R8184G4066
Manufacturer:
HONEYWELL
Honeywell Protectorelay R8184G4082 Oil Burner Control
    With 45 sec safety timing and alarm outputs
  • Provides automatic, nonrecycling control of an intermittent ignition oil burner system
  • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • Enclosed safety switch with external reset button
  • Manual trip lever opens safety switch for system maintenance
  • Mounts on standard 4 x 4" junction box, select models may be mounted directly on burner housing
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
  • 75 VA at 120/240 VAC, 50-60 Hz, 25 VA at 24V, 50-60 Hz alarm load ratings(pilot duty)

    Honeywell R75-44

Item#:
R75-44
Manufacturer Item:
R8184G4082
Manufacturer:
HONEYWELL
View: