ActionsSid Harvey C322-4R Dual Aquastat, 130 - 240 deg F High Limit, 110 - 220Sid Harvey Item #:C322-4R: Replaces Part #:'s : C322-4A,
,
,
Item#:
C322-4R
Manufacturer Item:
L4081B1096-1047
Manufacturer:
SID HARVEY REMANUFACTURED
Honeywell L8124G1020 High Limit Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
- Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
- Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Electrical burner rating: full load - 7.4 amp at 120 VAC line voltage, 3.7 amp at 240 VAC; locked rotor - 44.4 amp at 120 VAC line voltage, 22.7 amp at 240 VAC
- Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor
Sid Harvey Honeywell L8124C High Limit Triple Aquastat Relay, 120 VAC, SPST, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit
,
- Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Select models include large transformers and extra terminals for supplying power to low voltage zone valves
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
,
Item#:
C317-5R
Manufacturer Item:
L8124C1003
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell Pressuretrol PA404A Pressure Controller with additive differential, 0.5 - 9 psi, 3-3/8 Inch W x 4-15/32 Inch H x 2-1/4 Inch D
- Pressure actuated high limit, safety control for steam heating boilers, It breaks an electrical circuit to shut down the burner if steam pressure rises above a safe level
- Contains an SPST Micro switch snap-acting switch
- Sensitive pressure actuated diaphragm expands or contracts with pressure variations, moving a lever mechanism which operates the snap switch
- A screw on top of the case allows setpoint adjustment without removing the cover
- Differential is adjusted by means of a dial located inside the case
- Recommended minimum setpoint is differential setting plus 1-1/2 psi
- Stainless steel diaphragm sensor element
- Makes at setpoint on pressure fall breaks at setpoint plus differential on pressure rise Honeywell Pressuretrol PA404A Pressure Controller with additive differential, 0.5 - 9 psi, 3-3/8 Inch W x 4-15/32 Inch H x 2-1/4 Inch D,
Item#:
C354R
Manufacturer Item:
PA404A1033
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C434-12R Fan limit Control 8'' REMANUFACTURED,
,
,
Item#:
C434-12R
Manufacturer Item:
C434-12R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C317R Triple Aquastat, 110 - 220 deg F Low Limit, 130 - 240 deg F High Limit, 10 - 25 deg F Adjustable Low Limit, 10 deg F Fixed High Limit Differential, SPST, 120 VAC, Remanufactured
- Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water
- Provides multi zone control by using a separate circulator and relay for each zone
- Includes diaphragm power head and Micro-Switch assembly that respond to temperature changes in boiler water
- Mounts directly to boiler
- Requires a 24 VAC thermostat with heat anticipator set at 0.2 ampSid Harvey Item #:C317R: Replaces Part #:'s : AQU8124A1007-C317-2B | C317-2B | C317-2R,
,
Item#:
C317R
Manufacturer Item:
L8024A
Manufacturer:
SID HARVEY REMANUFACTURED
Honeywell L8124E High Limit Triple Aquastat Relay, 120 VAC, SPST, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit
- Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
Mount directly to boiler - Select models include large transformers and extra terminals for supplying power to low voltage zone valves
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Item#:
C317-7R
Manufacturer Item:
L8124E1016
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured A28-69R Motor 1/3 HP 115 VAC 1725 RPM CW W/Bracket REMANUFACTURED
Item#:
A28-69R
Manufacturer Item:
131-143RP
Manufacturer:
SID HARVEY REMANUFACTURED
Bell & Gossett 189100 Bearing Assembly for Obsolete 1, 1-1/4, 1-1/2 Inch Cast Iron Circulators
Item#:
B70R
Manufacturer Item:
189100
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey A166R Vacuum Motor 7/8 HP REMANUFACTURED,
,
,
Item#:
A166R
Manufacturer Item:
HARVEY VACUUM
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Taco B163-80R Taco Powerhead 551,552,553, 24 VAC REMANUFACTURED,
,
,
Item#:
B163-80R
Manufacturer Item:
B163-80R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey B163-5R Zone Valve Motor Only REMANUFACTURED,
,
,
Item#:
B163-5R
Manufacturer Item:
V8043F1036
Manufacturer:
SID HARVEY REMANUFACTURED