S2K Commerce - Products Dropdown
ActionsS2K Commerce - Shopping Cart
ActionsS2K Commerce - Order Entry
ActionsSid Harvey Honeywell R8184M Oil Burner Primary Control for C554A Cadmium Sulfide Cell and 24VAC Thermostat, 120/26.5 VAC , 9 amp
,
,
Sid Harvey Honeywell R8184G4009 Non-Recycle Oil Burner Control with Safety Timing, 120/220/240 VAC
,
- Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
- Solid state flame sensing circuit
- LED on terminal strip indicates system lockout
- Remote lockout indication
- Enclosed safety switch with external reset butTon
- Manual trip lever opens safety switch for system maintenance
- Mounts on standard 4 x 4" junction box
- C554A cadmium sulfide flame detector and 24 VAC thermostat required
- With 15 sec safety timing, alarm outputs and manual safety switch
,
Item#:
R75-40R
Manufacturer Item:
R8184G4009
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey B163-14R Power Head Assembly V8043E-B REMANUFACTURED,
,
,
Item#:
B163-14R
Manufacturer Item:
V8043E-B
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell Protectorelay RA116A Universal Relay, 120 VAC , 75 sec Nominal
,
- Interrupted ignition type
- Combine a Protectorelar unit for cycling the burner and a Pyrostat flame detector for sensing temperature changes of flue gases up to 1000 deg F
- Manual reset of safety switch required after ignition failure completely shuts off main burner
- Include manual trip safety switch to assure burner shutdown during servicing
- Mount with flange for mounting on curved or flat surfaces
- Works with 2-wire and 3-wire 24 VAC thermostat
- 2 years warranty
,
Sid Harvey Remanufactured R20R
Item#:
R20R
Manufacturer Item:
RA116A
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell Protectorelay RA117A Universal Relay, 120 VAC , 75 sec Nominal
,
- Interrupted ignition type
- Combine a Protectorelar unit for cycling the burner and a Pyrostat flame detector for sensing temperature changes of flue gases up to 1000 deg F
- Manual reset of safety switch required after ignition failure completely shuts off main burner
- Include manual trip safety switch to assure burner shutdown during servicing
- Mount with flange for mounting on curved or flat surfaces
- Works with 2-wire and 3-wire 24 VAC thermostat
- 2 years warranty
,
Item#:
R22R
Manufacturer Item:
RA117A
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey R5R Interrupted Ignition Stack Relay, 120 volt, Remanufactured
- Remanufactured with 100% pure, solid silver pyrostat contacts for longer on-the-job service life
- Backed by 2-year warranty
- All new stack relays contain brass contacts covered with a slight silver plating, it wears off as the contacts open and close, exposing the brass surface over time, the exposed surface is a poor conductor and may result in relay failure and nuisance callbacksSid Harvey Item #:R5R: Replaces Part #:'s : 0R541R,
,
Item#:
R5R
Manufacturer Item:
RA817A
Manufacturer:
SID HARVEY REMANUFACTURED
Bell & Gossett 185333LF Lead-Free Maintenance Free Large Frame Seal Bearing Assembly, 5/8" Bore
,
- Permanently lubricated bearings
,
Bell & Gossett 185333LF
Sid Harvey Remanufactured B112-8R Electric Water Feeder 24 VAC REMANUFACTURED,
,
,
Item#:
B112-8R
Manufacturer Item:
169500
Manufacturer:
SID HARVEY REMANUFACTURED
McDonnell & Miller Series 101A Electric Water Feeder 120 VAC 25 psi OEM Number 169400 REMANUFACTURED
Sid Harvey Mcdonnell & Miller 169400 Electric Water Feeder, 2350000 BTU/hr Output, Import
- Eliminates necessity to manually add water to the boiler
- Can be used with mechanical or electronic low water cut-off controls
- Quick-change replaceable cartridge valve and strainer
- Manual feed button Mcdonnell & Miller 169400 Electric Water Feeder, 2350000 BTU/hr Output, Import,
,Sid Harvey Remanufactured B112-10R
Item#:
B112-10R
Manufacturer Item:
169400
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured B109R Complete Pump Cut-Off control,
,
,
Item#:
B109R
Manufacturer Item:
171702
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Mcdonnell & Miller 47-2 Mechanical Water Feeder, 3/4 Inch NPT Threaded, 120/240 VAC
- Continuous maintenance of minimum safe water level, independent of electrical service
- Proportional feed action
- Quick hook-up fittings provided
- Quick change replaceable cartridge valve and strainer
- Model 47 can be field upgraded with a No #2 switch to add low water cut-off function Mcdonnell & Miller 47-2 Mechanical Water Feeder, 3/4 Inch NPT Threaded, 120/240 VAC,
,Sid Harvey Remanufactured B110-1R
Item#:
B110-1R
Manufacturer Item:
132800
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey B110R Mechanical Water Feeder for Steam and Hot Water Boilers with Cold Water Feed, 25 psi, 120/240 VAC, Remanufactured
- Continuous maintenance minimum safe water level, independent of electrical device
- Direct action feeder mechanism
- Quick hook-up fittings provided (new only)
- Quick-change replaceable cartridge valve and strainer
- Quiet, durable operation
- Isolated feed valve minimizes lime and scale build-up
- Blow-off valve
- Burner switch cut-off,
,
Item#:
B110R
Manufacturer Item:
47
Manufacturer:
SID HARVEY REMANUFACTURED