|◀ 109 - 120 of 202 ▶|
View:
Sid Harvey Honeywell L8124C High Limit Triple Aquastat Relay, 120 VAC, SPST, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit
  • Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Select models include large transformers and extra terminals for supplying power to low voltage zone valves
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Sid Harvey Item #:C317-5R: Replaces Part #:'s : C317-5R,
,

Item#:
C317-5R
Manufacturer Item:
L8124C1003
Manufacturer:
SID HARVEY REMANUFACTURED
Honeywell L8124E High Limit Triple Aquastat Relay, 120 VAC, SPST, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit
  • Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water Mount directly to boiler
  • Select models include large transformers and extra terminals for supplying power to low voltage zone valves
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Sid Harvey Item #:C317-7R: Replaces Part #:'s : C317-7

Item#:
C317-7R
Manufacturer Item:
L8124E1016
Manufacturer:
SID HARVEY REMANUFACTURED
Honeywell L8124G1020 High Limit Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
  • Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Electrical burner rating: full load - 7.4 amp at 120 VAC line voltage, 3.7 amp at 240 VAC; locked rotor - 44.4 amp at 120 VAC line voltage, 22.7 amp at 240 VAC
  • Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor


Item#:
C317-8R
Manufacturer Item:
L8124G1020
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell L8124L High Limit Triple Aquastat Relay, 24 - 120 VAC, SPST, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit
  • Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Select models include large transformers and extra terminals for supplying power to low voltage zone valves
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Sid Harvey Item #:C317-11R: Replaces Part #:'s : AQU8124L1011-C317-11 | C317-11 |,
,

Item#:
C317-11R
Manufacturer Item:
L8124L1011
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell L8124A High and Low Limit Circulator Triple Aquastat Relay, 120 VAC, 130 - 240 deg F Adjustable High Limit, 110 - 220 deg F Adjustable Low Limit
  • Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Select models include large transformers and extra terminals for supplying power to low voltage zone valves
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Sid Harvey Item #:C317-2R: Replaces Part #:'s : AQU8124A1007-C317-2B | C317-2B | C317R,
,

Item#:
C317-2R
Manufacturer Item:
L8124A1007,1015,1098
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey B74-2R Hi-Temperature Bearing Assembly, 3/4 - 1-1/2 Inch Size,,
,

Item#:
B75-1R
Manufacturer Item:
189034
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured R80-52R Protectorelay & Hydronic Heating Controller for Oil Hydronic System REMANUFACTURED,
,

Item#:
R80-52R
Manufacturer Item:
R8182E
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey R80-58R Combination Protectorelay and Hydronic Heating Controller, 120 VAC, 4.4 amp Full Load, 26.4 amp Locked Rotor Burner at 120 VAC, 9 watt, Remanufactured
  • Immersion type aquastat controller and oil burner primary control provides high limit and low limit/circulator control for oil-fired hydronic heating systems
  • Use in intermittent ignition applications
  • Capable of zone control with zone valves
  • Circulator zone control with ZC and ZR terminals on R8182D, E, H, J
  • 8-flame failure during the running cycle results in a 45 sec attempt to restart
  • If unsuccessful, safety shutoff occurs, requiring manual reset before burner can be restarted
  • C554A cadmium sulfide flame detector and a 24 VAC thermostat required
  • Includes auxiliary ZC and ZR terminals may be used to provide circulator zone control through an R845A switching relay, horizontal case
  • Maximum 250 deg F at element, 15 deg F fixed high limit differential temperature
  • 45 sec safety switch timing
  • 1/2"-14 NPT well spud size
  • 0.2 amp anticipator setting
  • 1-1/2" insulation depth,
    ,

Item#:
R80-58R
Manufacturer Item:
R8182J1059
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured R80-40R Combination Protectorelay 5' Remote Bulb REMANUFACTURED,
,

Item#:
R80-40R
Manufacturer Item:
R8182H1070
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured R80-30R Combination Protectorelay (W/Well Adapter) REMANUFACTURED,
,

Item#:
R80-30R
Manufacturer Item:
R8182D1079
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured R80-32R Control Relay Combination Control Horizontal REMANUFACTURED,
,

Item#:
R80-32R
Manufacturer Item:
R8182D1111
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured R75-41R Oil Burner Primary Control R8184G Plastic Box 15 Second REMANUFACTURED,
,

Item#:
R75-41R
Manufacturer Item:
R75-41R
Manufacturer:
SID HARVEY REMANUFACTURED
|◀ 109 - 120 of 202 ▶|
View: