Sid Harvey Honeywell R8184M Oil Burner Primary Control for C554A Cadmium Sulfide Cell and 24VAC Thermostat, 120/26.5 VAC , 9 amp
,
,
Sid Harvey Honeywell R8184G4009 Non-Recycle Oil Burner Control with Safety Timing, 120/220/240 VAC
,
- Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
- Solid state flame sensing circuit
- LED on terminal strip indicates system lockout
- Remote lockout indication
- Enclosed safety switch with external reset butTon
- Manual trip lever opens safety switch for system maintenance
- Mounts on standard 4 x 4" junction box
- C554A cadmium sulfide flame detector and 24 VAC thermostat required
- With 15 sec safety timing, alarm outputs and manual safety switch
,
Item#:
R75-40R
Manufacturer Item:
R8184G4009
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell Protectorelay RA116A Universal Relay, 120 VAC , 75 sec Nominal
,
- Interrupted ignition type
- Combine a Protectorelar unit for cycling the burner and a Pyrostat flame detector for sensing temperature changes of flue gases up to 1000 deg F
- Manual reset of safety switch required after ignition failure completely shuts off main burner
- Include manual trip safety switch to assure burner shutdown during servicing
- Mount with flange for mounting on curved or flat surfaces
- Works with 2-wire and 3-wire 24 VAC thermostat
- 2 years warranty
,
Item#:
R20R
Manufacturer Item:
RA116A
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell Protectorelay RA117A Universal Relay, 120 VAC , 75 sec Nominal
,
- Interrupted ignition type
- Combine a Protectorelar unit for cycling the burner and a Pyrostat flame detector for sensing temperature changes of flue gases up to 1000 deg F
- Manual reset of safety switch required after ignition failure completely shuts off main burner
- Include manual trip safety switch to assure burner shutdown during servicing
- Mount with flange for mounting on curved or flat surfaces
- Works with 2-wire and 3-wire 24 VAC thermostat
- 2 years warranty
,
Item#:
R22R
Manufacturer Item:
RA117A
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey R5R Interrupted Ignition Stack Relay, 120 volt, Remanufactured
- Remanufactured with 100% pure, solid silver pyrostat contacts for longer on-the-job service life
- Backed by 2-year warranty
- All new stack relays contain brass contacts covered with a slight silver plating, it wears off as the contacts open and close, exposing the brass surface over time, the exposed surface is a poor conductor and may result in relay failure and nuisance callbacksSid Harvey Item #:R5R: Replaces Part #:'s : 0R541R,
,
Item#:
R5R
Manufacturer Item:
RA817A
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey 3001157 Primary Control Box for F3/F5/F10/M3/M5/M10 Riello Burner, 110 VAC at 60 Hz
,
,
Item#:
R78-10R
Manufacturer Item:
3001157
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey White Rodgers Cooling Controls 668-401 Gray Metal Enclosure Kwik-Sensor CAD Cell Relay, 120 VAC, 45 sec
- Intermittent ignition kwik-sensor CAD cell relays on oil burner systems with 15, 30 or 45 sec safety timing
- Certain types have unique signal-light feature with glows whenever safety lock-out occurs
- Line voltage safety switch eliminates burner run-on in the event that the motor relay contacts weld closed
- Solid state flame detection circuitry is not affected by vibration or high or low ambient temperatures
- Recycles on momentary flame failure or power interruption
- 4 x 4 Inch junction box, 10 Inch leads mounting
- 2 wire thermostat
- 0.4 amp thermostat anticipator setting
- Safety lock-out lamp White Rodgers Cooling Controls 668-401 Gray Metal Enclosure Kwik-Sensor CAD Cell Relay, 120 VAC, 45 secSid Harvey Item #:R79-6R: Replaces Part #:'s : R79-6,
,
Item#:
R79-6R
Manufacturer Item:
668-401
Manufacturer:
SID HARVEY REMANUFACTURED