Sid Harvey Honeywell R8184G4009 Non-Recycle Oil Burner Control with Safety Timing, 120/220/240 VAC
,
- Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
- Solid state flame sensing circuit
- LED on terminal strip indicates system lockout
- Remote lockout indication
- Enclosed safety switch with external reset butTon
- Manual trip lever opens safety switch for system maintenance
- Mounts on standard 4 x 4" junction box
- C554A cadmium sulfide flame detector and 24 VAC thermostat required
- With 15 sec safety timing, alarm outputs and manual safety switch
,
Item#:
R75-40R
Manufacturer Item:
R8184G4009
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey R80-58R Combination Protectorelay and Hydronic Heating Controller, 120 VAC, 4.4 amp Full Load, 26.4 amp Locked Rotor Burner at 120 VAC, 9 watt, Remanufactured
- Immersion type aquastat controller and oil burner primary control provides high limit and low limit/circulator control for oil-fired hydronic heating systems
- Use in intermittent ignition applications
- Capable of zone control with zone valves
- Circulator zone control with ZC and ZR terminals on R8182D, E, H, J
- 8-flame failure during the running cycle results in a 45 sec attempt to restart
- If unsuccessful, safety shutoff occurs, requiring manual reset before burner can be restarted
- C554A cadmium sulfide flame detector and a 24 VAC thermostat required
- Includes auxiliary ZC and ZR terminals may be used to provide circulator zone control through an R845A switching relay, horizontal case
- Maximum 250 deg F at element, 15 deg F fixed high limit differential temperature
- 45 sec safety switch timing
- 1/2"-14 NPT well spud size
- 0.2 amp anticipator setting
- 1-1/2" insulation depth,
,
Item#:
R80-58R
Manufacturer Item:
R8182J1059
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured R80-52R Protectorelay & Hydronic Heating Controller for Oil Hydronic System REMANUFACTURED,
,
,
Item#:
R80-52R
Manufacturer Item:
R8182E
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey 3001157 Primary Control Box for F3/F5/F10/M3/M5/M10 Riello Burner, 110 VAC at 60 Hz
,
,
Item#:
R78-10R
Manufacturer Item:
3001157
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured R80-40R Combination Protectorelay 5' Remote Bulb REMANUFACTURED,
,
,
Item#:
R80-40R
Manufacturer Item:
R8182H1070
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey R75-61R 2-Wire CAD Cell Relay, 24 volt, Remanufactured
- Ignition comes on for duration of safety timing if flame fails during operationSid Harvey Item #:R75-61R: Replaces Part #:'s : R75-61R,
,
Item#:
R75-61R
Manufacturer Item:
R8404AA
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured R75-29R Cad Cell Relay Intermittent 45 Second,
,
,
Item#:
R75-29R
Manufacturer Item:
R4184A,D
Manufacturer:
SID HARVEY REMANUFACTURED