S2K Commerce - Products Dropdown
ActionsS2K Commerce - Shopping Cart
ActionsS2K Commerce - Order Entry
ActionsBrand Name
Type
Amperage
Voltage
Diversitech 7-CRNR50 Dual Element Class RK5 Current-Limiting Time-Delay Fuse, 50 amp, 250 VAC
,
- Provides time delay for temporary over-current conditions and motor running protection
- Eliminates unnecessary maintenance from harmless overloads
,
Bussmann E356-44
Item#:
E356-44
Manufacturer Item:
ECNR-50
Manufacturer:
COOPER BUSSMAN LLC
Bussmann E356-20 Fuse Dual Element 3.2 AMP S Base
Heavy-duty, dual-element, time-delay rejection base fuse
Use to protect critical motor circuits or motors that cycle on or off frequently
Features non-interchangeable body
An industrial or commercial grade product with dual-element construction
These fuses thread into SA adapters
Industrial strength, featuring an exclusive dual-element construction
This spring loaded design provides superior short circuit and overload protection,
,
,
Item#:
E356-20
Manufacturer Item:
S-3-2/10
Manufacturer:
COOPER BUSSMAN LLC
Bussmann 626-HASR30 Class RK5 Time-Delay Fuse, 30 amp, 600 VAC
,
- These plugs offer safe protection during momentary overload
- No adapter necessary
,
Bussmann E356-57
Item#:
E356-57
Manufacturer Item:
ECSR-30
Manufacturer:
COOPER BUSSMAN LLC
Mitco Fujitsu E397-600 Glass Fuse 3 AMP
Bussmann TL-15 Plastic Class RK4 Edison Base Plug Time-Delay Fuse, 15 amp, 125 VAC
,
- Will withstand typical motor starting surges
- These fuses thread into fuse receptacles or box cover units for supplemental protection
- Brass threads
- Time-delay pass motor overload starting currents without opening and allow closer sizing to motor load for added protection
,
Bussmann E356-15
Item#:
E356-15
Manufacturer Item:
TL-15
Manufacturer:
COOPER BUSSMAN LLC
The time-delay characteristics of these fuses typically allows them to be sized closer to the running ampacity of inductive loads to reduce cost and provide improved overcurrent protection. These fuses will override normal equipment current surges to reduce unnecessary fuse openings. Have moderate current limitation.
,
- True dual-element construction allows sizing of 125% FLA for motor backup protection
- Superior overload and cycling capabilities
- Provides motor overload, ground fault and short-circuit protection
- Helps protect motors against burnout from overloads and also from single phasing on three phase systems
- Current limiting provides component short circuit protection
- Simplifies and improves blackout prevention
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance, short circuit and overload protection
- The overload element provides protection against low level over current of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
,
Bussmann E356-48
Item#:
E356-48
Manufacturer Item:
ECNR-100
Manufacturer:
MOTORS & ARMATURES CO
Sid Harvey E397-425 2-Pole Interchangeable Circuit Breaker 20 AMP,
,
,
Sid Harvey E397-425
Item#:
E397-425
Manufacturer Item:
E397-425
Manufacturer:
MITCO MFG.
Recommended for AC power distribution system mains, feeders and branch circuits having inductive loads motors, transformers or non-inductive loads lighting, heating, typically allows them to be sized closer to the running ampacity of inductive loads to reduce cost and provide improved overcurrent protection, override normal equipment current surges to reduce unnecessary fuse openings.
- True dual-element construction allows sizing of 125% FLA for motor backup protection
- Superior overload and cycling capabilities
- Provides motor overload, ground fault and short-circuit protection
- Helps protect motors against burnout from overloads and also from single phasing on three phase systems
- Current limiting provides component short circuit protection
- Simplifies and improves blackout prevention
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance, short circuit and overload protection
- The overload element provides protection against low level over current of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds ,
,Bussmann E356-42A
Item#:
E356-42A
Manufacturer Item:
ECNR-35
Manufacturer:
COOPER BUSSMAN LLC
Bussmann 7-CRNR15 Dual Element Class RK5 Current-Limiting Time-Delay Fuse, 15 amp, 250 VAC
,
- Provides time delay for temporary over-current conditions and motor running protection
- Eliminates unnecessary maintenance from harmless overloads
,
Bussmann E356-40
Item#:
E356-40
Manufacturer Item:
ECNR-15
Manufacturer:
COOPER BUSSMAN LLC
Recommended for AC power distribution system mains, feeders and branch circuits having inductive loads motors, transformers or non-inductive loads lighting, heating, typically allows them to be sized closer to the running ampacity of inductive loads to reduce cost and provide improved overcurrent protection, override normal equipment current surges to reduce unnecessary fuse openings.
,
- True dual-element construction allows sizing of 125% FLA for motor backup protection
- Superior overload and cycling capabilities
- Provides motor overload, ground fault and short-circuit protection
- Helps protect motors against burnout from overloads and also from single phasing on three phase systems
- Current limiting provides component short circuit protection
- Simplifies and improves blackout prevention
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance, short circuit and overload protection
- The overload element provides protection against low level over current of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
,
Bussmann E356-34
Item#:
E356-34
Manufacturer Item:
ECNR-5
Manufacturer:
COOPER BUSSMAN LLC
Sid Harvey E397-209 Glass Fuse Assortment 0.25 0.5 0.75 1 2 3 AMP,
,
,
Sid Harvey E397-209
Item#:
E397-209
Manufacturer Item:
E397-209
Manufacturer:
MITCO MFG.
The time-delay characteristics of these fuses typically allows them to be sized closer to the running ampacity of inductive loads to reduce cost and provide improved overcurrent protection. These fuses will override normal equipment current surges to reduce unnecessary fuse openings. Have moderate current limitation.
,
- True dual-element construction allows sizing of 125% full load ampere for motor backup protection
- Superior overload and cycling capabilities
- Current limiting provides component short-circuit protection
- Provides motor overload, ground fault and short-circuit protection
- Helps to protect motors against burnout from overloads and also from single-phasing on three-phase systems
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short-circuit and overload protection
- The overload element provides protection against low level over current of overloads and will hold an overload which is 5-times greater than the ampere rating of the fuse for a minimum of 10 sec
- Simplifies and improves blackout prevention selective coordination
,
Bussmann E356-39
Item#:
E356-39
Manufacturer Item:
ECNR-10
Manufacturer:
COOPER BUSSMAN LLC