ActionsSunrise Electric Supply 808C Device Mount 1/2" Raised Square Exposed Work Cover, 4.19" W x 4.19" H
Item#:
808C
Manufacturer Item:
808C
Manufacturer:
Hubbell-Raco
Sunrise Electric Supply Device Mount 1/2" Raised Square Exposed Work Cover, 4.19" W x 4.19" H,
Item#:
907C
Manufacturer Item:
907C
Manufacturer:
Hubbell-Raco
Sunrise Electric Supply 902C Device Mount 1/2" Raised Square Exposed Work Cover, 4.19" W x 4.19" H
,
- Include required hardware for mounting the receptacle(s)
- No bonding jumper is required for covers with: (1) crushed corners (2) two or more device attachment screws (3) a lock washer or equivalent
- Hardware and cover are packed in a poly-bag with printed catalog number, compliances and installation instructions
,
Item#:
902C
Manufacturer Item:
050169-99995
Manufacturer:
Hubbell-Raco
Electro-Deposition Painted Heavy Zinc-Coated Steel 3-PH Fused Top Open A/C Disconnect, 60 amp at 240 volt,
,
,
Morris 10414 Yellow Electro Tin-Plated Brass Fully Insulated Female Disconnect, 12 - 10 AWG, 300 volt
Item#:
10414
Manufacturer Item:
10414
Manufacturer:
CROWN ELECTRIC SUPPLY CO.LTD
Sid Harvey E306-001 Disconnect Fused 30 Amp,
,
,
Item#:
E306-001
Manufacturer Item:
E306-001
Manufacturer:
MITCO MFG.
Mars side open disconnect boxes are contractor friendly and feature a unique side opening door, allowing easy access to the work area. The powder coated UV rated finish provides superior esthetics and greater longevity. The patented"finger safe" pullout section prevents accidental contact with electrodes. Easy to remove knockouts and a secure locking mechanism are also featured. This pullout disconnect box is the ideal choice for the busy contractor.,
,
,
York A/C Parts S1-3500-3261 Disconnect Switch with Plug
Item#:
S1-3500-3261
Manufacturer Item:
S1-3500-3261
Manufacturer:
YORK INTERNATIONAL CORP.
Mars 80308 Disconnect W/GFI Receptacle 60 Amp Non-Fused
The time-delay characteristics of these fuses typically allows them to be sized closer to the running ampacity of inductive loads to reduce cost and provide improved overcurrent protection. These fuses will override normal equipment current surges to reduce unnecessary fuse openings. Have moderate current limitation.
,
- True dual-element construction allows sizing of 125% FLA for motor backup protection
- Superior overload and cycling capabilities
- Provides motor overload, ground fault and short-circuit protection
- Helps protect motors against burnout from overloads and also from single phasing on three phase systems
- Current limiting provides component short circuit protection
- Simplifies and improves blackout prevention
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance, short circuit and overload protection
- The overload element provides protection against low level over current of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
,
Item#:
E356-48
Manufacturer Item:
ECNR-100
Manufacturer:
MOTORS & ARMATURES CO
The time-delay characteristics of these fuses typically allows them to be sized closer to the running ampacity of inductive loads to reduce cost and provide improved overcurrent protection. These fuses will override normal equipment current surges to reduce unnecessary fuse openings. Have moderate current limitation.
- True dual-element construction allows sizing of 125% FLA for motor backup protection
- Superior overload and cycling capabilities
- Provides motor overload, ground fault and short-circuit protection
- Helps protect motors against burnout from overloads and also from single phasing on three phase systems
- Current limiting provides component short circuit protection
- Simplifies and improves blackout prevention
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance, short circuit and overload protection
- The overload element provides protection against low level over current of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
Item#:
E356-46
Manufacturer Item:
ECNR-70
Manufacturer:
COOPER BUSSMAN LLC
Bussmann 7-CRNR15 Dual Element Class RK5 Current-Limiting Time-Delay Fuse, 15 amp, 250 VAC
,
- Provides time delay for temporary over-current conditions and motor running protection
- Eliminates unnecessary maintenance from harmless overloads
,
Item#:
E356-40
Manufacturer Item:
ECNR-15
Manufacturer:
COOPER BUSSMAN LLC