Home  > PARKER HANNIFIN(AFTERMARKET)(x)
|◀ 121 - 132 of 241 ▶|
View:
Parker C-EC-SC Series Balance Ported Thermostatic Expansion Valve Body
  • 3/8" x 1/2" ODF
  • 1/6-1/2 HP
  • The SC(E) series brass body expansion valve incorporates a 90 deg elbow inlet with a removable strainer
  • External
  • R404A


Item#:
SCE-AA-SW
Manufacturer Item:
SBFSE-AA-C
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker PCK-48HH Replaceable Charcoal Burnout Filter Drier Core
  • Formulated with charcoal to remove wax on low temperature systems even before problems occur. It can be used in either liquid or suction line applications and also removes acids, water, solids and sludge. Recommended for refrigerant reclaim/recovery units.

,

Item#:
PCK-48HH
Manufacturer Item:
031812-00
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker 203818 Gasket Kit for use with A82, L Types Flo-Con Valves, Port Valve 13-21, Solenoid Valve 13-21
    ,

    Item#:
    203818
    Manufacturer Item:
    203818
    Manufacturer:
    PARKER HANNIFIN(AFTERMARKET)
    Parker LAC head pressure control valves have a brass body with copper connections. These valves are nonadjustable. They perform the function of limiting flow of refrigerant from the condenser and at the same time regulate the flow of hot gas around the condenser to the receiver during low ambient conditions, so as to keep the refrigerant in the liquid line at proper pressure. Each valve is factory tested to ensure positive leak-free performance.
    • 180 PSI
    • 1/2" OD
    ,
    ,

    Item#:
    LAC-4-180-1/2OD
    Manufacturer Item:
    903038P
    Manufacturer:
    PARKER HANNIFIN(AFTERMARKET)
    Parker LAC head pressure control valves have a brass body with copper connections. These valves are nonadjustable. They perform the function of limiting flow of refrigerant from the condenser and at the same time regulate the flow of hot gas around the condenser to the receiver during low ambient conditions, so as to keep the refrigerant in the liquid line at proper pressure. Each valve is factory tested to ensure positive leak-free performance.
    • 210 PSI
    • 1/2" OD
    ,
    ,

    Item#:
    LAC-5-210-1/2OD
    Manufacturer Item:
    903071P
    Manufacturer:
    PARKER HANNIFIN(AFTERMARKET)
    Parker LAC head pressure control valves have a brass body with copper connections. These valves are nonadjustable. They perform the function of limiting flow of refrigerant from the condenser and at the same time regulate the flow of hot gas around the condenser to the receiver during low ambient conditions, so as to keep the refrigerant in the liquid line at proper pressure. Each valve is factory tested to ensure positive leak-free performance.
    • 295 PSI
    • 1/2" OD
    ,
    ,

    Item#:
    LAC-4-295HP-1/2OD
    Manufacturer Item:
    903111P
    Manufacturer:
    PARKER HANNIFIN(AFTERMARKET)
    The ORD valve is a pressure differential valve that responds to changes in the pressure difference across the valve, Figure 6 on the next page. The valve designation stands for Opens on Rise of Differential pressure. Therefore, the ORD is dependent on some other control valve or action for its operation. And in this respect, it is used with the ORI for head pressure control. As the ORI valve starts to throttle the flow of liquid refrigerant from the condenser, a pressure differential is created across the ORD. When the differential reaches setpoint, the ORD starts to open and bypasses hot gas to the liquid drain line. As the differential increases, the ORD opens further until its full stroke is reached at a differential of 10 psi above setpoint. Due to its function in the control of head pressure, the full stroke can be utilized in selecting the ORD. The standard pressure setting for the ORD is 20 psig. For systems where the pressure drop between the compressor and the receiver is higher than 14 psi, an ORD with a higher setting is available.
    • 20 PSI
      • 5/8" OD

    Item#:
    ORD-4-20
    Manufacturer Item:
    902877
    Manufacturer:
    PARKER HANNIFIN(AFTERMARKET)
    Parker LAC head pressure control valves have a brass body with copper connections. These valves are nonadjustable. They perform the function of limiting flow of refrigerant from the condenser and at the same time regulate the flow of hot gas around the condenser to the receiver during low ambient conditions, so as to keep the refrigerant in the liquid line at proper pressure. Each valve is factory tested to ensure positive leak-free performance.
    • 100 PSI
    • 3/8" OD
    ,
    ,

    Item#:
    LAC-4-100-3/8OD
    Manufacturer Item:
    903017P
    Manufacturer:
    PARKER HANNIFIN(AFTERMARKET)
    Parker LAC head pressure control valves have a brass body with copper connections. These valves are nonadjustable. They perform the function of limiting flow of refrigerant from the condenser and at the same time regulate the flow of hot gas around the condenser to the receiver during low ambient conditions, so as to keep the refrigerant in the liquid line at proper pressure. Each valve is factory tested to ensure positive leak-free performance.
    • 180 PSI
    • 3/8" OD
    ,
    ,

    Item#:
    LAC-4-180-3/8OD
    Manufacturer Item:
    903024P
    Manufacturer:
    PARKER HANNIFIN(AFTERMARKET)
    Parker LAC head pressure control valves have a brass body with copper connections. These valves are nonadjustable. They perform the function of limiting flow of refrigerant from the condenser and at the same time regulate the flow of hot gas around the condenser to the receiver during low ambient conditions, so as to keep the refrigerant in the liquid line at proper pressure. Each valve is factory tested to ensure positive leak-free performance.
    • 210 PSI
    • 3/8" OD

    ,
    ,


    Item#:
    LAC-4-210-3S
    Manufacturer Item:
    903005P
    Manufacturer:
    PARKER HANNIFIN(AFTERMARKET)
    Parker LAC head pressure control valves have a brass body with copper connections. These valves are nonadjustable. They perform the function of limiting flow of refrigerant from the condenser and at the same time regulate the flow of hot gas around the condenser to the receiver during low ambient conditions, so as to keep the refrigerant in the liquid line at proper pressure. Each valve is factory tested to ensure positive leak-free performance.
    • 100 PSI
    • 5/8" OD
    ,
    ,

    Item#:
    LAC-5-100-5/8OD
    Manufacturer Item:
    903050P
    Manufacturer:
    PARKER HANNIFIN(AFTERMARKET)
    Parker LAC head pressure control valves have a brass body with copper connections. These valves are nonadjustable. They perform the function of limiting flow of refrigerant from the condenser and at the same time regulate the flow of hot gas around the condenser to the receiver during low ambient conditions, so as to keep the refrigerant in the liquid line at proper pressure. Each valve is factory tested to ensure positive leak-free performance.
    • 180 PSI
    • 5/8" OD
    ,
    ,

    Item#:
    LAC-5-180-5/8OD
    Manufacturer Item:
    903029P
    Manufacturer:
    PARKER HANNIFIN(AFTERMARKET)
    |◀ 121 - 132 of 241 ▶|
    View: