Sid Harvey L8151A is a remote bulb controller for use with hydronic heating systems that include domestic hot water service.
  • Provides high limit, low limit and circulator control for maintaining boiler temperatures
  • Can provide multizone control by using a separate thermostat and R845 Relay for each zone
  • An internal transformer powers the thermostat circuit
  • Shielded capillary allows convenient mounting
  • Consists of a diaphragm powerhead and micro switch assembly that responds to temperature changes in the boiler water
  • Mounting lugs on back of case
,
,

Item#:
C317-13R
Manufacturer Item:
L8151A
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey High Limit Aquastat Relay 8F differential REMANUFACTURED. Immersion type controllers that combine high limit protection with switchingrelay control of burner and circulator motors
  • High limit opens burner circuit only.
  • Includes transformer and accessory terminals for adding a remote low limit controller.
  • Case available for horizontal or vertical mounting.
  • Requires a 24 VAC thermostat with heat anticipator set at 0.2 amps.
Sid Harvey Item #:C312-8R: Replaces Part #:'s : 0R257,
,

Item#:
C312-8R
Manufacturer Item:
L8148A1017
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell L8124A High and Low Limit Circulator Triple Aquastat Relay, 120 VAC, 130 - 240 deg F Adjustable High Limit, 110 - 220 deg F Adjustable Low Limit
  • Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Select models include large transformers and extra terminals for supplying power to low voltage zone valves
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Sid Harvey Item #:C317-2R: Replaces Part #:'s : AQU8124A1007-C317-2B | C317-2B | C317R,
,

Item#:
C317-2R
Manufacturer Item:
L8124A1007,1015,1098
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C290-1R Bronze Close On Rise Aquastat, 100 - 240 deg F, Remanufactured
  • 3" insulation, stop factory set at 240 deg F, well adapter and heat conductive compound includes,
    ,

Item#:
C290-1R
Manufacturer Item:
L4006B1155-1163
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell L8124L High Limit Triple Aquastat Relay, 24 - 120 VAC, SPST, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit
  • Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Select models include large transformers and extra terminals for supplying power to low voltage zone valves
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Sid Harvey Item #:C317-11R: Replaces Part #:'s : AQU8124L1011-C317-11 | C317-11 |,
,

Item#:
C317-11R
Manufacturer Item:
L8124L1011
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C434-9R Fan Limit Control, Remanufactured
  • ,
    ,

Item#:
C434-9R
Manufacturer Item:
C434-9
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C434-7R Fan limit Control 5'' REMANUFACTURED,
,

Item#:
C434-7R
Manufacturer Item:
C434-7R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C354-1R Pressuretrol Controller, SPST, 0.5-9 psi Adjustable, 3-3/8" W x 4-15/32" H x 2-1/4" D, Remanufactured
  • The PA404 is a series 40 (2-wire, SPST) pressuretrol controller for use in 24, 120, 240 or 277 volt control circuits or in self powered (millivoltage) applications
  • The PA404B is used with suspension-type unit heaters to make the fan circuit when a pressure rise indicates the presence of steam
  • Each model contains an SPST micro-switch snap-acting switch
  • Sensitive pressure-actuated diaphragm expands or contracts with pressure variations, moving a lever mechanism which operates the snap switch
  • A screw on top of the case allows set point adjustment without removing the cover
  • Differential is adjusted by means of a dial located inside the case
  • Recommended minimum set point is differential setting plus 1-1/2 psi
  • Tradeline value
  • Stainless steel diaphragm sensor element
  • Additive or subtractive differential type
  • Makes at set point plus differential on pressure rise, breaks at set point on pressure fall
  • 50 psi pressure surge
  • 0.5-9 psi adjustable scale range,

Item#:
C354-1R
Manufacturer Item:
PA404B1023
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C346-73R Heat Timer EPU-CH Blue Panel REMANUFACTURED,
,

Item#:
C346-73R
Manufacturer Item:
C346-73R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C322-4R Dual Aquastat, 130 - 240 deg F High Limit, 110 - 220Sid Harvey Item #:C322-4R: Replaces Part #:'s : C322-4A,
,

Item#:
C322-4R
Manufacturer Item:
L4081B1096-1047
Manufacturer:
SID HARVEY REMANUFACTURED
Honeywell L8124G1020 High Limit Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
  • Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Electrical burner rating: full load - 7.4 amp at 120 VAC line voltage, 3.7 amp at 240 VAC; locked rotor - 44.4 amp at 120 VAC line voltage, 22.7 amp at 240 VAC
  • Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor


Item#:
C317-8R
Manufacturer Item:
L8124G1020
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell L8124C High Limit Triple Aquastat Relay, 120 VAC, SPST, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit
  • Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Select models include large transformers and extra terminals for supplying power to low voltage zone valves
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Sid Harvey Item #:C317-5R: Replaces Part #:'s : C317-5R,
,

Item#:
C317-5R
Manufacturer Item:
L8124C1003
Manufacturer:
SID HARVEY REMANUFACTURED