ActionsPackard C240B 2-Pole Definite Purpose Contactor, 120 VAC at 50/60 Hz, 40 amp
,
- Includes lugs, spade terminals and covers
- Class B coil insulation
- 50 amp resistive, 200 amp at 240, 160 amp at 480 volt, 120 amp at 600 volt locked rotor
,
Packard C240C 2-Pole Definite Purpose Contactor, 208/240 VAC at 50/60 Hz, 40 amp
,
- Includes lugs, spade terminals and covers
- Class B coil insulation
- 50 amp resistive, 200 amp at 240, 160 amp at 480 volt, 120 amp at 600 volt locked rotor
,
Packard C240A 2-Pole Definite Purpose Contactor, 24 volt at 50/60 Hz, 40 amp
- Includes lug, spade terminals and covers
- Coils have class B insulation
- 40 amp resistive, 180 amp at 240 volt, 150 amp at 480 volt, 120 amp at 600 volt locked rotor
Packard C325A 3-Pole Definite Purpose Contactor, 24 VAC at 50/60 Hz, 25 amp
,
,
- 25 amp full load inductive, 35 amp resistive, 150 amp at 240, 125 amp at 480 volt, 100 amp at 600 volt locked rotor
- Coils have class B insulation
- Includes lug, spade terminals and covers
,
,
Packard C330B 3-Pole Definite Purpose Contactor, 120 volt at 50/60 Hz, 30 amp
,
- Includes lug, spade terminals and covers
- Coils have class B insulation
- 40 amp resistive, 180 amp at 240 volt, 150 amp at 480 volt, 120 amp at 600 volt locked rotor
,
Packard C330C 3-Pole Definite Purpose Contactor, 208/240 volt at 50/60 Hz, 30 amp
- Includes lug, spade terminals and covers
- Coils have class B insulation
- 40 amp resistive, 180 amp at 240 volt, 150 amp at 480 volt, 120 amp at 600 volt locked rotor
Packard C330C
Packard C330A 3-Pole Definite Purpose Contactor, 24 volt at 50/60 Hz, 30 amp
- 40 amp resistive, 180 amp at 240 volt, 150 amp at 480 volt, 120 amp at 600 volt locked rotor
- Coils have class B insulation
- Includes lug, spade terminals and covers
Packard C330A
Packard C340B 3-Pole Definite Purpose Contactor, 120 volt at 50/60 Hz, 40 amp
,
- Includes lug, spade terminals and covers
- Coils have class B insulation
- 50 amp resistive, 240 amp at 240 volt, 200 amp at 480 volt, 160 amp at 600 volt locked rotor
,
Packard C340C 3-Pole Definite Purpose Contactor, 208/240 volt at 50/60 Hz, 40 amp
- Includes lug, spade terminals and covers
- Coils have class B insulation
- 50 amp resistive, 240 amp at 240 volt, 200 amp at 480 volt, 160 amp at 600 volt locked rotor
Packard C340C
Packard C340A 3-Pole Definite Purpose Contactor, 24 volt at 50/60 Hz, 40 amp
Packard C350B 3-Pole Definite Purpose Contactor, 120 VAC at 50/60 Hz, 50 amp
,
- 50 amp full load inductive, 65 amp resistive, 300 amp at 240, 250 amp at 480 volt, 200 amp at 600 volt locked rotor
- Includes lugs, spade terminals and covers
- Coils have class B insulation
,
Packard C350C 3-Pole Definite Purpose Contactor, 208/240 volt at 50/60 Hz, 50 amp
,
- Includes lug, spade terminals and covers
- Coils have class B insulation
- 65 amp resistive, 300 amp at 240 volt, 250 amp at 480 volt, 200 amp at 600 volt locked rotor
,