ActionsHoneywell THP2400A1068/U Square Cover Plate Assembly for Lyric T6 Pro, T6
Item#:
THP2400A1068
Manufacturer Item:
THP2400A1068
Manufacturer:
HONEYWELL
Honeywell THM5320R1000/U Gray Non-Programmable RF Equipment Remote Module, Up to 2 Heat/2 Cool Conventional, Up to 3 Heat/2 Cool Heat Pump, 18 - 30 VAC
,
- Easily relocate thermostat or upgrade equipment without running new wires using this module and a wireless FocusPRO thermostat
- Powered by RedLink reliability
- No interference with other wireless devices in the home
- Works with TH6320R1004 or TH5320R1002 wireless FocusPRO thermostats
- Input for return air sensor
- Quick connect terminal blocks
- LED for power and system status
,
Honeywell THM5320R1000
Item#:
THM5320R1000
Manufacturer Item:
THM5320R1000
Manufacturer:
HONEYWELL
,
HONEYWELL T822K1000
Item#:
T822K1000
Manufacturer Item:
T822K1000
Manufacturer:
HONEYWELL
Honeywell T775R2035 Electronic Temp Controller W/2 Temp Inputs 2 SPDT Relays,
,
,
Item#:
T775R2035
Manufacturer Item:
T775R2035/U
Manufacturer:
HONEYWELL
Honeywell T775B2040 Temperature Control -10-248 Degree 4 SPDT
- The T775 electronic remote temperature controllers are the next generation of commercial and agricultural controls capable of remote sensing of temperature and providing switched and/or proportional outputs to various types of loads
- Save time on installations with the easy-to-use graphical Interface, large display, and the intuitive programming
- Use the time clock scheduler or digital input to control the setback and disable output options to help save energy
- Protect equipment from freezing or overheating on models with the modulating high or low limit control option
- Get pinpoint control on modulating outputs by setting the integral and derivative times (PI or PID)
- Configure models with reset in a few easy steps
- Control floating actuators with floating outputs on select models
- Eliminate the need for a separate time delay device and protect equipment with the minimum off time option
- Includes 50021579-001 Sensor with non-NEMA4X models;
- T775-SENS-WR Sensor with NEMA4X models
- Set point range: -40° to 248°F
- Differential temperature: 1° to 150°F
- Heat or cool
- 24/120/240VAC, 50/60Hz
- UL Listed, CE approved,
,
,
HONEYWELL T87K1007
Item#:
T87K1007
Manufacturer Item:
T87K1007
Manufacturer:
HONEYWELL
,
HONEYWELL T822K1018
Item#:
T822K1018
Manufacturer Item:
T822K1018
Manufacturer:
HONEYWELL
Honeywell TC500A Thermostat Commerical Wireless RTU/HP
Item#:
T775A2009
Manufacturer Item:
T775A2009
Manufacturer:
HONEYWELL
Honeywell T775U2006 Humidity Control 2-SPDT 2-Inputs
- Universal model (T775U) can control pressure, humidity, or any variable analog input
- Special boiler model (T775P) for boiler control.
- Special Staged Sequencing Model (T775L) for sequence staging of relays with one or two setpoints. S
- pecial Expansion Model (T775S) for staging up to 12 relays with two setpoints (each T775S provides 4 relays).
- Save time on installations with the easy-to-use graphical Interface, large display, and the intuitive programming.
- Use the time clock scheduler or digital input to control the setback and disable output options to help save energy.
- Provide very fast or very fast response times on modulating outputs by adjusting the integral and derivative times (PI or PID)
- Configure models with reset in a few easy steps
- Eliminate the need for a separate time delay device and protect equipment with the minimum off time option
- Use the T775L and T775P to stage up to 12 relays (with optional T775S) from two independent heat or cool setpoints
- Support for digital output alarm on the T775P configurable based on minimum, maximum, or differential temperature.,
,Honeywell T775U2006
Honeywell T775M2030 Temperature Control -40-248F 4-SPDT
- Remote sensor electronic modulating temperature control. Two inputs, four SPDT relay outputs. Includes 50021579-001 standard sensor. Range -40° to 248°F. Sensor element 1097 Ohm PTC at 77°F. On/off control for applications where electronic accuracy and remote sensing is required.,
Honeywell T675A1565 Temperature Control 0-100 Degrees 20' Capillary
- Remote bulb thermostats regulate temperature of air or liquids in ducts, pipes, tanks and boilers
- Suitable for applications requiring temperature control of air or liquids where controller must be placed outside the sensing area
- Typical uses include control of dampers and valves in heating, cooling and heating-cooling systems
- Fast response models (available for use in return air duct) operate approximately four times faster than standard models
- Controller can be mounted in any position
- Ambient temperature compensation provides good temperature control
- Refer to T775 Electronic Remote Temperature Controller where more exact control is required and/or remote controller location is preferred
- T675A Models: fixed differential have an electrical rating of 125VA at 120/208/240VAC and 277VAC
- T675B Models: 125VA pilot duty up to 277VAC
- T678 Models: maximum connected load of 2,000VA
- Frequency: 50/60Hz
- Dimensions: 5-5/8"H x 2"W x 2-5/8"D
- UL Listed, CSA certified,
,Honeywell T675A1565
Honeywell T675A1508 Temperature Control 0-100 Degrees 5' Capillary
- Remote bulb thermostats regulate temperature of air or liquids in ducts, pipes, tanks and boilers
- Suitable for applications requiring temperature control of air or liquids where controller must be placed outside the sensing area
- Typical uses include control of dampers and valves in heating, cooling and heating-cooling systems
- Fast response models (available for use in return air duct) operate approximately four times faster than standard models
- Controller can be mounted in any position
- Ambient temperature compensation provides good temperature control
- Refer to T775 Electronic Remote Temperature Controller where more exact control is required and/or remote controller location is preferred
- T675A Models: fixed differential have an electrical rating of 125VA at 120/208/240VAC and 277VAC
- T675B Models: 125VA pilot duty up to 277VAC
- T678 Models: maximum connected load of 2,000VA
- Frequency: 50/60Hz
- Dimensions: 5-5/8"H x 2"W x 2-5/8"D
- UL Listed, CSA certified,