S2K Commerce - Products Dropdown
ActionsS2K Commerce - Shopping Cart
ActionsS2K Commerce - Order Entry
ActionsField Controls 01950201 10" M+MG2 barometric draft control for gas and oil type M+MG2 barometric draft controls overview solid, oil or gas commercial/industrial, this is a series of compact, rugged, heavy-duty controls for use on large residential, commercial, and industrial applications. The Field Type M+MG2 draft control provides precise draft regulations for solid fuels, oil, gas, or oil/gas appliances requiring only the simplest, on-the-job adjustments depending on which fuel is to be utilized. In a gas installation, the double-acting Type M+MG2 is specified instead of a draft hood to give the appliance the assistance of the chimney. In a duel fuel oil/gas or a gas-fired only application, use the M+MG2 as a double-acting draft control with the optional Field Thermal Switch accessory. Use the M+MG2 as a single-acting draft control for oil or solid fuel applications. For any installation with 10" or larger diameter vent pipe, specify our standard M+MG2 Draft Control, the unit that can be adapted to any fuel. The moving part (gate) rests on a long, thin, stainless steel knife edge which, in turn, is supported by self-aligning and self-cleaning bearings. When the heavy gauge gate moves, only the knife edge rests on the bearing for minimum friction and maximum sensitivity to draft changes.
,
,
Field Controls 100-4
The Field RC is furnished as standard equipment on many leading brands of oil or coal-fired heating equipment. It is calibrated to allow for easy adjustment to the furnace or boiler manufacturer's specifications. Designed for settings from 0.02 - 0.08", this control is so sensitive that instrumentation should be used when adjusting the unit during installation.
,
,
Field Controls 100-30
Field Controls 00963801 Silver Barometric Draft Control for Residential Oil, Wood and Coal, 6"
,
- M control lends itself ideally to conditions requiring a great deal of stability and accuracy
- Designed for settings from 0.01 - 0.1"
- Type M features an infinitely variable screw adjustment, permitting an extremely fine instrument setting
- M employs side wings to control air direction with gate curvatures designed to compensate for differences in horizontal and vertical settings
,
The Field RC is furnished as standard equipment on many leading brands of oil or coal-fired heating equipment. It is calibrated to allow for easy adjustment to the furnace or boiler manufacturer's specifications. Designed for settings from 0.02 - 0.08", this control is so sensitive that instrumentation should be used when adjusting the unit during installation.
,
,
Field Controls 100-22
Field Controls 02724001 Silver Barometric Draft Control for Gas-Fired Furnaces and Boilers is Widely Used for Conversion Burner Installations, Gas Atmospheric Appliances, 6"
,
- 28.3 sq-inch capacity
- 5 - 6" pipe size
- 24 ga (ring and gate), 26 ga (collar) thickness
- Because it is double acting, it opens out to relieve positive vent system pressures as low as 0.01"
- Can improve combustion stability and draft on many gas atmospheric installations with venting problems
- Provides precise, accurate control of drafts at levels higher than permitted by a standard draft diverter
,
Field Controls 100-10
Field Controls 100-11 Barometric Draft Damper Gas 7" A double-acting control for gas-fired furnaces and boilers is widely used for conversion burner installations, gas draft-induced appliance operation with mechanical draft inducers, or sidewall power venters. It is also recommended for use on gas atmospheric appliances where a draft hood cannot be installed, and can improve combustion stability and draft on many gas atmospheric installations with venting problems. The MG-1 provides precise, accurate control of drafts at levels higher than permitted by a standard draft diverter, which is a frequent requirement with gas.
,
,
Field Controls 100-11
Tjernlund 100-12 Barometric Draft Damper Gas 7"-8",
,
,
Item#:
100-12
Manufacturer Item:
01986501
Manufacturer:
FIELD CONTROLS LLC
Weil-McLain Heating Parts 382200345 Blower Fan Motor Replacement Kit GVGV90+ Boilers,
,
,
Item#:
382200345
Manufacturer Item:
382-200-345
Manufacturer:
FIELD CONTROLS LLC
Field Controls CAS-2C Air Boot Kit for Carlin EZ-1, CRD and FRD Oil Burners, 2 gph
,
- Provide controlled amount of outside air for proper combustion of oil heating appliances
- Connect directly to oil burners
- Too tight construction
,
Field Controls CAS-2C Air Boot Kit for Carlin EZ-1, CRD and FRD Oil Burners, 2 gph
,
- Provide controlled amount of outside air for proper combustion of oil heating appliances
- Connect directly to oil burners
- Too tight construction
,
Field Controls SK-6 CAP Chimney Rain Cap 6",
,
,
Item#:
602609900
Manufacturer Item:
602609900
Manufacturer:
FIELD CONTROLS LLC