Sealed Unit Parts UET240 Universal, Adjustable, Electronic Defrost Timer, 10 - 35 min
Item#:
UET240
Manufacturer Item:
UET240
Manufacturer:
SEALED UNIT PARTS CO, INC
Paragon 8145-20M Steel Defrost Timer, 208/240 VAC , 4 - 110 min in 2 min The Paragon 8000 series commercial defrost controls are designed for commercial freezers and refrigerators to provide automatic defrost capability. They accommodate various types of defrost systems including electric defrost heaters, hot gas, and compressor off cycle
Item#:
8145-20M
Manufacturer Item:
8145-20M
Manufacturer:
ROBERTSHAW CONTROLS CO.
Sealed Unit Parts SPG1401GE Plastic Heavy-Duty Defrost Timer, 120 volt, 15 amp
    Domestic refrigerators and freezers
  • 6 hr cycle time
Item#:
SPB1401F
Manufacturer Item:
SPB1401F
Manufacturer:
SEALED UNIT PARTS CO, INC
Sealed Unit Parts C265 Universal Electronic Defrost Timer
    1-35 Min Spdt 12 Vac 1 Amp Max 10 Amp
Item#:
C265
Manufacturer Item:
EDT10
Manufacturer:
SEALED UNIT PARTS CO, INC
Item#:
C255-150
Item#:
C255-140
Item#:
C255-130
Item#:
C255-132
Robertshaw Controls C255-136 Defrost Timer 240 VAC
Item#:
C255-136
Manufacturer Item:
8143-20
Manufacturer:
ROBERTSHAW CONTROLS CO.
The Paragon 8000 series commercial defrost controls are designed for commercial freezers and refrigerators to provide automatic defrost capability. They accommodate various types of defrost systems including electric defrost heaters, hot gas, and compressor off cycle.
    Positive slide bar switch design assures positive electrical contact and wipes the contact surface of contaminates
  • Temperature or pressure terminated models are designed to stop defrosting using an external temperature or pressure device
  • Safety back-up - mechanical time-driven defrost termination
  • Heavy-duty synchronous design drive motor
  • Choice of 3-contact arrangements
  • Adjustable frequency of defrost initiation from 1 - 6-cycles per day with a minimum of 4 hr between successive operations
  • Adjustable back-up defrost termination from 4 - 110 min in 2 min increments
  • Have an adjustable cut-in pressure dial calibrated from 36 - 110 lb for R12, R22, R502
  • Time initiated/temperature or pressure terminated
  • Open switch arrangement for contacts 1 - 3, closed switch arrangement for contacts 2 - 4
  • Electric heat, hot gas or compressor shutdown
  • 1 year limited warranty
Item#:
C255-138
Manufacturer Item:
8145-00
Manufacturer:
ROBERTSHAW CONTROLS CO.